defining a degree of excellence
Radial Leaded PTC
RoHS6 Compliant
0ZRE Series
0ZRE1007D
Electrical Characteristics (23°C)
Application
Line Voltage Power Supply, Transformer and
Appliances
Product Features
Continuous Use at Voltages up to 240V AC/DC,
Low Hold Current, 265V AC/DC Max
Interrupt Voltage
Operating (Hold Current) Range
50mA ~ 550mA
Maximum Operating Voltage
240VAC/DC
Maximum Interrupt Voltage
265VAC/DC
Hold current-maximum current at which the device will not trip in still air at 23°C.
Trip current-minimum current at which the device will always trip in still air at 23°C.
Maximum fault current device can withstand without damage at rated voltage (Vmax).
Maximum voltage device can withstand without damage at its rated current.
Typical power dissipated by device when in tripped state in 23°C still air environment.
Minimum device resistance at 23°C.
IH
IT
Temperature Range
-40°C to 85°C
Imax
Vmax
Pd
Agency Approval
TUV (Std. EN60738-1-1, Cert. R50102173)
UL Component (Std. UL1434, File E305051)
UL Conditions of Acceptability:
1.These devices have been investigated for
use in safety circuits and are suitable as a limiting
device.
Rmin
Rmax
R1max
Maximum device resistance at 23°C.
Maximum device resistance at 23°C, 1 hour after initial device trip.
Physical specifications
Lead material
Product Dimensions
0ZRE0005 ~ 0ZRE0016 - Tin plated copper clad steel, 24AWG.
0ZRE0025 ~ 0ZRE0040 - Tin plated copper, 22AWG.
0ZRE0055 - Tin plated copper, 20AWG.
Soldering characteristics
Fig 1
Fig 2
MIL-STD-202, Method 208E.
Insulating coating
Flame retardant epoxy, meets UL-94-V-0 requirements.
All dimensions
in mm
PTC Marking
H
“bel” or “b”, I code and “RE”.
ø
Standard Package
Specifications subject to change without noticeG
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel:201 - 432 - 0463 • Fax:201 - 432 - 9542 • E-Mail: belfuse@belfuse.com
Website:www.belfuse.com