General Purpose Relays
Power Relay 430
I
I
I
I
I
I
I
1 pole 16 A or 2 pole 10 A in NO, CO and NC versions
DC- and AC-coil
4 kV / 8 mm coil-contact
PCB mounting or quick connect terminals
Mounting brackets or snap mounting
Product in accordance to IEC60335-1
RoHS compliant (Directive 2002/95/EC)
as per product date code 0349
Applications
F0257-A
Motors, electro valves
Approvals
V
1 pole: REG.-Nr. A548, 2 pole: REG.-Nr. A516,
Z
E214025
Technical data of approved types on request
Contact data
1-pole
2-pole
Contact configuration
Contact set
1CO, 1NO, 1NC
single contact
2CO, 2NO, 2NC
single contact
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Maximum breaking capacity AC
Limiting making capacity, max 4 s, duty factor 10% 25 A
Contact material
Mechanical endurance
Rated frequency of operation with / without load
micro disconnection micro disconnection
16 A
240/400 VAC
4000 VA
10 A
240/400 VAC
2500 VA
15 A
AgCu3, AgCdO
AgCu3, AgCdO
> 2,5x105 cycles
15 / 600 min-1
Contact ratings
Type
Load
Cycles
2,5x105
2,5x105
1 pole 16 A, 250 VAC, resistive
2 pole 10 A, 250 VAC, resistive
Coil data
Rated coil voltage range DC coil
AC coil
6...110 VDC
6...240 VAC
1 W
Coil power DC coil
AC coil
Operative range
1,8 VA
2
Coil versions, DC-coil
Coil
Rated
voltage
VDC
12
Operate
voltage
VDC
Release
voltage
VDC
0.6
Coil
resistance
Ohm
145+10%
580+10%
2200+10%
13000+10%
7500+10%
Rated coil
power
mW
993
993
1047
931
480
code
09
10
11
13
03
7.8
24
15.6
1.2
48
110
60
31.2
2.4
71.5
5.5
42.0
4.5
Coil versions, AC-coil 50Hz
Coil
code
Rated
voltage
VAC
24
Operate
voltage
VAC
Release
voltage
VAC
3.6
Coil
resistance
Ohm
200+10%
1250+10%
4500+10%
17500+10%
7500+10%
Rated coil
power
VA
03
05
06
07
03
18.0
1.8
60
45.0
9.0
1.8
110
83.0
16.0
35.0
4.5
1.8
230
170.0
42.0
1.8
60
1.8
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet
Rev. EK1
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
‘Schrack’ section.
Issued 2005/11
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
www.tycoelectronics.com
www.schrackrelays.com
Specifications subject to
change.