Cord & Cordset
Industrial Cord
Carolprene® Welding Cable
90ºCꢀ600ꢀVolt
Product Construction:
Conductor:
•ꢀ 6ꢀ ꢀAWGꢀthroughꢀ500ꢀkcmilꢀfullyꢀannealedꢀ
strandedꢀbareꢀcopperꢀClassꢀK
ꢀ
Jacket:
ꢀ
ꢀ
•ꢀ Premium-gradeꢀ90ºCꢀEPDM,ꢀblackꢀorꢀred
•ꢀ Tꢀ emperatureꢀrange:ꢀ-40ºCꢀtoꢀ+90ºC
Jacket Marking:
•ꢀ Cꢀ AROLPRENEꢀ(SIZE)ꢀWELDINGꢀCABLEꢀ600ꢀ
CAROLPRENE® WELDING CABLE – 600 VOLT – CLASS K – 30 AWG STRANDING
ꢀ
APPROX.
VOLT MADE IN USA
NOMINAL O.D.
CATALOG
NUMBER
AWG OR
kcmil
CONDUCTOR
STRAND
NET WT.
STD.
CTN.
Applications:
•ꢀ Sꢀ econdaryꢀvoltageꢀresistanceꢀweldingꢀleads
•ꢀ Pꢀ owerꢀsupplyꢀapplicationsꢀnotꢀexceedingꢀ
600 volts AC
INCHES
mm
LBS/M'(S)
ꢀ
ꢀ
6
259/30
374/30
0.380
0.400
0.465
0.495
0.560
0.615
0.670
0.750
0.830
0.960
1.200
9.65
10.16
11.81
12.57
14.22
15.62
17.02
19.05
21.08
24.38
30.48
135
172
260
317
400
487
605
827
976
1338
1995
250'
250'
250'
250'
250'
250'
250'
250'
250'
250'
250'
01778
01777
01776
01775
01774
01773
01772
01771
99142*
99432*
99202*
4
Features:
•ꢀ Goodꢀflexibility
•ꢀ Aꢀ brasion-resistant
•ꢀ Gꢀ oodꢀcolorꢀretention
2
1
625/30
ꢀ
ꢀ
ꢀ
778/30
1/0
990/30
Packaging:
•ꢀ 2ꢀ 50'ꢀ(76.2ꢀm),ꢀ500'ꢀ(152.4ꢀm),ꢀandꢀ1000'ꢀ
(304.8ꢀm)ꢀreels
•ꢀ Mꢀ CMꢀsizesꢀcutꢀtoꢀlength
•ꢀ Oꢀ therꢀput-upsꢀavailableꢀonꢀspecialꢀorder
2/0
1248/30
1586/30
2054/30
2496/30
3432/30
5054/30
ꢀ
3/0
ꢀ
ꢀ
4/0
250 kcmil
350 kcmil
500 kcmil
Industry Approvals:
•ꢀ RoHSꢀCompliant
ꢀ
(S) Actual shipping weight may vary.
Non-stock item, minimum quantity required.
Suggested Ampacities:
*
For 600 Volt In-Line Applications
AWG OR kcmil AMPERES
AWG
1/0
1
AMPERES
190
WELDING CABLE AMPACITIES
SINGLE CONDUCTOR
500 kcmil
350 kcmil
250 kcmil
4/0
695
552
445
310
265
223
160
2
140
RequiredꢀCableꢀSizes:ꢀForꢀWeldingꢀCableꢀApplication
4
100
length in feet for total circuit for secondary voltages only – do not use this table for 600 Volt in-line applications
100' 150' 200' 250' 300' 350' 400'
1/0 1/0
3/0
6
75
AMPS
100
2/0
4
4
2
1
4
2
2
1
2
1
Ampacities for portable cable, continuous-duty
(ambientꢀtemperatureꢀofꢀ40°C).
150
200
250
300
350
400
450
500
550
600
1/0
2/0
3/0
4/0
2/0
3/0
4/0
3/0
4/0
3/0
4/0
1
1/0
2/0
3/0
4/0
May not be suitable for all installations per
National Electrical Code®.
1/0
2/0
3/0
3/0
4/0
4/0
4/0
1/0
1/0
2/0
2/0
3/0
3/0
4/0
Ordering Part Number Example
01771.38.03
4/0ꢀ500'ꢀput-upꢀinꢀred
.03 for red jacket
REQUIRED CABLE SIZES SHOWN IN AWG NUMBERS
Theꢀtotalꢀcircuitꢀlengthꢀincludesꢀbothꢀweldingꢀandꢀgroundꢀleadsꢀ(basedꢀonꢀ4-voltꢀdrop)ꢀ60%ꢀdutyꢀcycle.
These values for current-carrying capacityꢀareꢀbasedꢀonꢀaꢀcopperꢀtemperatureꢀofꢀ60°Cꢀ(140°F),ꢀanꢀambientꢀtemperatureꢀ
ofꢀ40°Cꢀ(104°F)ꢀandꢀyieldꢀloadꢀfactorsꢀfromꢀapproximatelyꢀ32%ꢀforꢀtheꢀNo.ꢀ2ꢀAWGꢀcableꢀtoꢀapproximatelyꢀ23%ꢀforꢀ
theꢀNo.ꢀ3/0ꢀAWGꢀcable,ꢀandꢀhigherꢀforꢀtheꢀsmallerꢀsizes.ꢀTheꢀsizesꢀofꢀcablesꢀgenerallyꢀusedꢀrangeꢀfromꢀNo.ꢀ2ꢀAWGꢀtoꢀ
No. 3/0 AWG. In actual service, the load factor may be much higher than indicated without overheating the cable, as the
ambient temperature will generally be substantially lower than 40°C.
34