0.5D14B_3UP Series
0.5W - Single Output DC-DC Converter - Fixed Input - Isolated & Unregulated
DC-DC Converter
The 0.5D14B_3UP series are miniature, isolated 0.25W DC/DC converters
in a SIP and DIP package.
0.5 Watt
Short circuit protection (SCP)
3KVDC Isolation
Power density up to 0.85W/cm3
Power sharing on dual output
Industry standard pinout
RoHS compliance
Temperature range:
-40°C ~ +105°C
They offer the ideal solution in many space critical applications for
board level power distribution. The internal SMD construction makes it
possible to offer a product with high performance at low cost. The
series offers smaller size, improved efficiency, lower output ripple noise
and 3KVDC isolation.
Efficiency up to 80%
Footprint from 1.17cm3
Common specifications
Short circuit protection:
Cooling:
Output specifications
Continuous, self-recovery
Free air convection
-40°C~+105°C
Item
Test condition
Min
Typ
Max Units
Output voltage
accuracy
See tolerance envelope
graph
Operation temperature range:
Storage temperature range:
Lead temperature:
Storage humidity range:
Power density:
Line regulation
Ripple & Noise*
Temperature drift
From high to low Vin
20MHz Bandwidth
100% full load
1
1.32
75
%
-50°C ~+130°C
50
mVp-p
%/°C
300°C MAX, 1.5mm from case for 10 sec
0.03
< 95%
< 0.85W/cm3
Switching frequency • 3.3VDC input
• 5VDC input
95
kHz
kHz
kHz
kHz
120
145
90
140
180
180
• 12VDC input
• 15VDC input
Case material:
Plastic [UL94-V0]
>3,500,000 hours
2.1g (SIP), 2.4g (DIP)
MTBF (MIL-HDFK-217F@25°C):
Weight:
* Ripple and noise are measured by “parallel cable” method, please see DC-DC
Converter Application Notes for specific operation.
Input specifications
Example DIP14 Case:
0.5D14B_0505S3UP
Item
Test condition
Min
Typ
Max
Units
0.5= 0.5 Watt; D14= DIP14; B= Pinning; 05= 5 Vin; 05= 5Vout;
S= Single Output; 3= 3kVDC Isolation; U= Unregulated Output;
P= Short circuit protection (SCP)
Input voltage range • 3.3VDC input
• 5VDC input
2.9
4.4
11
3.3
5
12
15
3.6
5.6
13.3
16.4
V
V
V
V
• 12VDC input
• 15VDC input
13.4
Note:
1. Operation under minimum load will not damage the converter; However, they
may not meet all specification listed, and that will reduce the life of product.
2. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage
and rated output load unless otherwise specified.
Isolation specifications
Item
Test condition
Min
Typ
Max
Units
VDC
Isolation voltage
Tested for 1 minute
and 1mA max
3000
3. Only typical models listed, other models may be different, please contact our
technical person for more details.
4. In this datasheet, all the test methods of indications are based on corporate
standards.
Isolation resistance
Test at 1000VDC
1
GΩ
Page 1 of 3
0.5D14B_3UP – Rev. 2018-1.0
Specifications subject to change without notice.
GAPTEC-Electronic GmbH & Co. KG