Cables for I/O Relay Terminals
XW2Z-R
Connect I/O Relay Terminals to I/O Units for
Programmable Controllers with one touch.
• Cables with Connectors for G70V and G7TC I/O Relay Terminals,
G70D and G70R Relay Terminals, and G70A and P7TF-IS/OS I/O
Terminal Sockets.
• Cables with loose wires available with or without crimp terminals.
• Cables available for programmable controllers from Mitsubishi Electric.
Cable Types and Table of Contents
Wiring diagram
Page Number
I/O
Connects to
Appearance
Description
Name
Typical model
Classification
This Cable is convenient for con-
necting I/O Relay Terminals to
devices equipped with screw ter-
minals.
Cables with Loose
Wires and Crimp
Terminals
16 I/O points
XW2Z-RYꢀC
(1)
Connections with termi-
nal blocks of various de-
vices
4
This Cable has loose wires at the Cables with Loose
16 I/O points
16 I/O points
XW2Z-RAꢀC
XW2Z-RꢀC
(2)
device end.
Wires
Connects a PLC I/O Unit, De-
viceNet slave or other device with Cables with Con-
(3)
Fujitsu connectors 1:1 to an I/O
nectors (1:1)
Relay Terminal.
5
32 input points
32 output points
XW2Z-RIꢀC-ꢀ
XW2Z-ROꢀC-ꢀ
(4)
Connects a PLC I/O Unit, De-
viceNet slave, or other device
with Fujitsu connectors 1:2 to I/O nectors (1:2)
Relay Terminals.
Fujitsu
connectors
Cables with Con-
(5)
Connects a PLC I/O Unit, De-
viceNet slave, or other device
with Fujitsu connectors 1:3 to I/O nectors (1:3)
Relay Terminals.
Cables with Con-
48 I/O points
XW2Z-RꢀC-ꢀ-ꢀ
6
7
(6)
Connects a PLC I/O Unit, De-
XW2Z-ROꢀC
XW2Z-RIꢀC
(7)
(8)
viceNet slave, or other device
with MIL connectors 1:1 to an I/O nectors (1:1)
Relay Terminal.
Cables with Con-
16 input points/
16 output points
XW2Z-ROꢀ-ꢀ-D1
(9)
Connects a PLC I/O Unit, De-
viceNet slave, or other device
with MIL connectors 1:2 to I/O
32 input points/
32 output points
MIL connectors
8
9
XW2Z-RIꢀ-ꢀ-D1
XW2Z-RIꢀ-ꢀ-D2
XW2Z-RMꢀ-ꢀ-D1
XW2Z-RMꢀ-ꢀ-D2
(10)
(11)
(12)
(13)
Relay Terminals.
Cables with Con-
nectors (1:2)
Connects a DeviceNet slave or
other device with MIL connectors
1:2 to I/O Relay Terminals.
16 input points/
16 output points
(32 I/O points)
Mitsubishi Electric PLCs
32 input points
32 output points
XW2Z-RIꢀC-MN
XW2Z-ROꢀC-MN
(14)
(15)
Applicable models:
For inputs:
AX42, A1SX41, A1SX42,
QX41, and QX42
For outputs:
AY42, A1SY41, A1SY42,
QY41P, and QY42P
Connects Mitsubishi Electric
PLCs with 32-point connectors to
I/O Relay Terminals through a
special cable.
Mitsubishi Electric
PLC Connecting
Cables (1:2)
10
Note: For combinations of Connections, refer to I/O Relay Terminals and Connected Devices (Cat. No. J217) or to the datasheets for related prod-
ucts.
1