Nexperia
XS3A1T5157
Low-ohmic single-pole double-throw analog switch
Table 8. ON resistance
At recommended operating conditions; voltages are referenced to GND (ground = 0 V); for graphs see Fig. 7 to Fig. 13.
Symbol Parameter Conditions Tamb = -40 °C to +85 °C Tamb = -40 °C to +125 °C Unit
Min
Typ[1]
Max
Min
Max
RON(peak) ON resistance VI = GND to VCC
;
(peak)
ISW = 100 mA; see Fig. 6
VCC = 1.4 V
-
-
-
-
-
1.6
1.0
3.7
1.6
-
-
-
-
-
4.1
1.7
0.9
0.9
0.9
Ω
Ω
Ω
Ω
Ω
VCC = 1.65 V
VCC = 2.3 V
0.55
0.5
0.8
VCC = 2.7 V
0.75
0.75
VCC = 4.3 V
0.5
ΔRON
ON resistance VI = GND to VCC
;
[2]
mismatch
between
channels
ISW = 100 mA
VCC = 1.4 V
VCC = 1.65 V
VCC = 2.3 V
VCC = 2.7 V
VCC = 4.3 V
-
-
-
-
-
0.04
0.04
0.02
0.02
0.02
0.3
0.2
-
-
-
-
-
0.3
0.3
0.1
0.1
0.1
Ω
Ω
Ω
Ω
Ω
0.08
0.075
0.075
RON(flat) ON resistance VI = GND to VCC
;
[3]
(flatness)
ISW = 100 mA
VCC = 1.4 V
VCC = 1.65 V
VCC = 2.3 V
VCC = 2.7 V
VCC = 4.3 V
-
-
-
-
-
1.0
0.5
3.3
1.2
0.3
0.3
0.4
-
-
-
-
-
3.6
1.3
Ω
Ω
Ω
Ω
Ω
0.15
0.13
0.2
0.35
0.35
0.45
[1] Typical values are measured at Tamb = 25 °C.
[2] Measured at identical VCC, temperature and input voltage.
[3] Flatness is defined as the difference between the maximum and minimum value of ON resistance measured at identical VCC and
temperature.
11.1. Test circuits and graphs
V
CC
switch
S
S
Z
Y1
Y2
1
2
V
IL
or V
IH
1
2
V
IH
switch
I
S
V
IL
GND
V
V
O
I
aaa-031202
VI = 0.3 V or VCC - 0.3 V; VO = VCC - 0.3 V or 0.3 V
Fig. 4. Test circuit for measuring OFF-state leakage current
©
XS3A1T5157
All information provided in this document is subject to legal disclaimers.
Nexperia B.V. 2020. All rights reserved
Product data sheet
Rev. 1 — 17 March 2020
6 / 19