XLamp® XB-H LED
FLuX CHAꢀACtEꢀiꢁtiCꢁ (tJ = 85 °C)
The following table provides several base order codes for XLamp XB‑H LEDs. It is important to note that the base order codes listed here
are a subset of the total available order codes for the product family. For more order codes, as well as a complete description of the
order‑code nomenclature, please consult the XLamp XB LED Family Binning and Labeling document.
Calcꢅlaꢂed
Mꢃꢄꢃmꢅm
Lꢅmꢃꢄꢆꢅs Flꢅx
(lm)**
Mꢃꢄꢃmꢅm Lꢅmꢃꢄꢆꢅs Flꢅx
CCt ꢀaꢄge
@ 700 mA
Cꢆlꢆr
order Cꢆde
@ 85 °C
Flꢅx
(lm) @
25 °C*
Flux (lm)
@ 85 °C
Mꢃꢄ.
Max.
Grꢆꢅp
1.0 A
1.5 A
T6
T5
T4
T3
T6
T5
T4
T3
T5
T4
T3
T4
T3
T4
T3
T2
T2
S6
S5
S6
S5
S4
280
260
240
220
280
260
240
220
260
240
220
240
220
240
220
200
200
182
172
182
172
164
322
299
276
253
322
299
276
253
299
276
253
276
253
276
253
230
230
209
198
209
198
186
372
345
318
292
372
345
318
292
345
318
292
318
292
318
292
265
265
242
228
242
228
218
499
463
428
392
499
463
428
392
463
428
392
428
392
428
392
356
356
324
306
324
306
292
XBHAWT‑00‑0000‑000LT60E1
XBHAWT‑00‑0000‑000LT50E1
XBHAWT‑00‑0000‑000LT40E1
XBHAWT‑00‑0000‑000LT30E1
XBHAWT‑00‑0000‑0000T60E3
XBHAWT‑00‑0000‑0000T50E3
XBHAWT‑00‑0000‑0000T40E3
XBHAWT‑00‑0000‑0000T30E3
XBHAWT‑00‑0000‑000LT50E4
XBHAWT‑00‑0000‑000LT40E4
XBHAWT‑00‑0000‑000LT30E4
XBHAWT‑00‑0000‑000HT40E5
XBHAWT‑00‑0000‑000HT30E5
XBHAWT‑00‑0000‑0000T40E7
XBHAWT‑00‑0000‑0000T30E7
XBHAWT‑00‑0000‑0000T20E7
XBHAWT‑00‑0000‑000PT20E7
XBHAWT‑00‑0000‑000PS60E7
XBHAWT‑00‑0000‑000PS50E7
XBHAWT‑00‑0000‑000US60E7
XBHAWT‑00‑0000‑000US50E7
XBHAWT‑00‑0000‑000US40E7
Cool White
5000 K
8300 K
Outdoor White
Neutral White
3200 K
5300 K
3700 K
2600 K
2600 K
5300 K
4300 K
3700 K
80‑CRI Minimum
White
Warm White
85‑CRI Minimum
White
2600 K
2600 K
3200 K
3200 K
90‑CRI Minimum
White
Notes:
•
Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and ±2 on
CRI measurements. See the Measurements section (page 9).
•
•
•
*
Typical CRI for Cool White (5000 K ‑ 8300 K CCT) is 70.
Typical CRI for Neutral White (3700 K ‑ 5300 K CCT) is 75.
Typical CRI for Warm White (2600 K ‑ 3700 K CCT) is 80.
Flux values @ 25 °C are calculated and for reference only.
** Calculated flux values at 1 A and 1.5 A are for reference only.
Copyright © 2014-2016 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree® and XLamp® are registered trademarks and the Cree logo is a trademark of
Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
3