Pre-amplified/3V Excitation/Gauge
X3GM-3,X3GM-6 Data sheet
Connection diagram
X3GM-3, X3GM-6
Vcc(DC3V)
Vcc
Vout
GND
Vout
C2
C1
Remarks :
1)C1 : Connect 680pF capacitor within 2cm distance from leads.
2)C2 : Connect 0.01 F or more capacitor within 2cm distance
from leads.
3)4 and 5 pins must be No Connection. Open them as floating
GND
ones completely, and do NOT connect to other line or each
other.
Transfer Function
Vout=Vs (P
Vs=3.0volts
+
)
(Pressure Error Temperature Error Multiplier
Vs)
Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage.
P=Input Pressure(kPa)
Model
050KPG(D)
100KPG(D)
100KPGV
100KPGW(DW)
200KPG(D)
001MPG(D)
115KPA
pressure range
Pressure Error(kPa)
0
0
50kPa
100kPa
100kPa
0.01
0.005
0.005
0.0025
0.0025
0.0005
0.005
0.1667
0.1667
0.1667
0.4167
0.1667
0.1667
0.09167
2.5
5.0
5.0
10.0
10.0
50.0
5.0
0
100 +100kPa
0
0
200kPa
1MPa
15 115kPa.abs
Temperature Error Multiplier=1
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
3
E-mail : sensor@fujikura.co.jp