Approval sheet
ESD
Test contact 1KV.
R/R max. (1%+0.5m)
No visible damage
AEC-Q200-002
Test ½ Sine Pulse, Peak value: 100g, normal duration: 6ms,
Velocity change:12.3ft/sec. Three shocks in each direction,
total 18 shocks.
Mechanical Shock
MIL-STD-202
method 213
Vibration
Within product specification tolerance and
no visible damage.
Test 5g’s for 20 min., 12 cycles each of 3 orientations.
No visible damage.
MIL-STD-202
method 204
Solvent is Isopropyl alcohol, immersion 3mins at 25℃ and
brush 10 strokes with a toothbrush with a handle made of a
non-reactive material (wet bristle), immersion and brush 3
times and then air blow dry.
No superficial defect on marking,
encapsulation, coating, appearance.
Electrical characteristics within products
specification and tolerance. Inspect at 3X
max. for marking, inspect at 10X for part
damage.
Resistance to Solvents :
MIL-STD-202
Method 215
Electrical test not required. Inspect device construction,
marking and workmanship
External Visual
MIL-STD-883
method 2009
Physical Dimension
JESD22
No visual damage and refer WTC marking
code.
Verify physical dimensions(L, W, T, Tb, Tt)
Within the specified tolerance for WTC.
method JB-100
Sulfuration test
ASTM B-809-95
ASTM B-809-95 105’C 1000hrs
R/R max. (2%+0.5m)
No visible damage
Page 7 of 8
ASC_WW25B_J_AUTO_V04
JUN 2020