WRA-YD-2W&WRB-YD-2W Series
2W, WIDE INPUT, ISOLATED & REGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER
SELECTION GUIDE
Input
Voltage(VDC)
Range
Output
Current(mA)
Efficiency
(%,Typ)
Order code
Voltage
(VDC)
Nominal
12
Max.*
22
Max.
Min.
WRA1205YD-2W
WRA1212YD-2W
WRA1215YD-2W
WRB1203YD-2W
WRB1205YD-2W
WRB1209YD-2W
WRB1212YD-2W
WRB1215YD-2W
WRA2405YD-2W
WRA2412YD-2W
WRA2415YD-2W
WRB2403YD-2W
WRB2405YD-2W
WRB2409YD-2W
WRB2412YD-2W
WRB2415YD-2W
9-18
9-18
±5
±12
±15
3.3
5
±200
±20
75
78
78
70
74
76
78
78
76
78
79
72
76
78
80
79
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
22
22
22
22
22
22
22
40
40
40
40
40
40
40
40
±83
±67
455
±8
±7
45
FEATURES
◆Miniature DIP package
9-18
9-18
9-18
400
40
◆2:1 wide input voltage range
◆Operating temperature: -40℃to +85℃
◆1500VDC isolation
9-18
9
222
22
9-18
12
167
16
9-18
15
133
13
◆No heat sink required
18-36
18-36
18-36
18-36
18-36
18-36
18-36
18-36
±5
±12
±15
3.3
5
±200
±83
±67
455
±20
±8
±7
45
◆No external component required
◆Industry standard pinout
◆Internal SMD construction
◆Short circuit protection(automatic recovery)
◆RoHS Compliance
400
40
9
222
22
12
167
16
15
133
13
*Input voltage can ' t exceed this value, or will cause the permanent damage.
MODEL SELECTION
⑥
①
②
③
④
⑤
WRB 24 05 Y D -2W
①Product Series
③Output Voltage
⑤DIP package style
②Input Voltage
④Wide (2:1) Input Range
⑥Rated Power
OUTPUT SPECIFICATIONS
Parameter
Storage humidity
Test conditions
Min.
Typ.
Max.
Units
95
85
%
℃
℃
℃
℃
W
Operating temperature
Storage temperature
Temp. rise at full load
Lead temperature
No-load power consumption
Cooling
-40
-55
125
APPLICATIONS
15
1.5mm from case for 10 seconds
300
The
WRA_YD-2W&WRB_YD-2W
series
are
0.2
specially designed for applications where
a
wide
Free air convection
range input voltage power supplies are isolated from
the input power supply in a distributed power supply
system on a circuit board. These products apply to:
1) Where the voltage of the input power supply is wide
range (voltage range≤2:1);
Short circuit protection
Case material
Continuous, automatic recovery
Plastic(UL94-V0)
MTBF
1000
K hours
Weight
4.8
g
2) Where isolation is necessary between input and
output(isolation voltage≤1500VDC);
3) Where the regulation of the output voltage and the
output ripple noise are demanded.
ISOLATION SPECIFICATIONS
Parameter
Isolation voltage
Test conditions
Min.
Typ.
85
Max.
Units
Tested for 1 minute and 1 mA max
Test at 500VDC
1500
1000
VDC
MΩ
pF
Isolation resistance
Isolation Capacitance
Input/Output, 100KHz/1V
MICRODC reserves the copyright
http://www.microdc.cn Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646