W6/W9 series  
Magnetic Hydraulic  
Circuit Breakers  
Typical Resistance and Impedance  
DC  
Features  
50/60 Hz.  
Impedance  
(Ohms)  
90  
400 Hz.  
Impedance  
(Ohms)  
180  
• Designed for the international market. UL Recognized, CSA Certified,  
and VDE approved.  
• Ratings to 50 amps.  
Current  
(Amps)  
0.2  
Resistance  
(Ohms)  
90  
• Heavy duty #10-32 stud connections. (W9)  
• Optional 10 amp auxiliary switch.  
• Optional snap-in mounting. (W6)  
• Several delay curve options.  
1.0  
2.0  
5.0  
10.0  
20.0  
30.0  
40.0  
50.0  
1.2  
0.28  
0.04  
0.013  
0.004  
0.0027  
0.002  
0.0015  
1.2  
0.28  
0.04  
0.013  
0.005  
0.004  
0.002  
0.0015  
2.0  
0.50  
0.05  
0.025  
0.0065  
0.004  
0.003  
Trip-free operation.  
0.0025  
Tolerance: 0.1 - 4.99 15%; 5 - 9.99 20%; 10 - 15 25%; 16 - 30 50%.  
Mechanical/Environmental Data  
Operating Temperature: -40°C to +85°C.  
Humidity: Meets requirements of Mil-STD-202 method 103.  
Shock: Tested per Mil-STD-202, method 213, test condition C  
(100g @ 6 ms).  
Vibration:Tested per Mil-STD-202, method 201, 10-55 Hz., 0.06" (1.52mm)  
total excursion in 2 planes.  
Agency Approvals  
UL: Recognized as Supplementary Protector under UL 1077. File  
E69543.  
CSA: Certified as a Supplementary Protector. File LR15734.  
VDE: Approved to VDE 0642/EN 60 934 (Circuit Breakers for Equipment)  
License No. 73782.  
Fungus And Moisture Resistance:Special moisture resistant finish  
applied to all ferrous parts.  
Plastic parts are made of inherently  
fungus resistant material.  
Electrical Data  
Marking: W6 units have ON and OFF molded on the rocker of rocker  
actuated units (rocker actuated VDE units have international  
“1” and “0”). W9 units have ON and OFF molded into the area  
at the base of the toggle. International “1” and “0” symbols are  
marked on the toggle for both W6 and W9.  
Mounting: Panel mounted units are mounted with two #6-32 screws  
from the front of the panel. Metric models for use with M3 x  
0.5 screws are available. Units with snap-in mounting option  
snap through the front of the panel. To maintain published  
performance specifications, units should not be mounted  
more than 90° from their normal upright position.  
Weight: Approximately 2.5 ounces per pole.  
Auxiliary Switch: See Auxiliary Switch Ratings Table 2 for details.  
Calibration: Breakers will hold 100% of rated current. Breakers may trip  
between 101% and 124% of rated load (149% for 400 Hz.  
units and 134% for AC/DC units). Breakers must trip at  
125% of rated load and above (150% for 400 Hz. units and  
135% for AC/DC units).  
Dielectric Strength: 50/60 or 400 Hz., 1500V: DC, 1100V.  
Insulation Resistance: 100 Megohms at 500VDC.  
Endurance: 10,000 on/off cycles - 6000 at rated load, 4000 at no load.  
Units tested at six cycles per minute, 1 second on and 9  
seconds off at 25°C ambient.  
Approvals and Ratings Table 1  
W6 Series  
UL/CSA (All Circuit Functions)  
W6 Series  
VDE (Circuit Function X)  
Current  
Phase  
Interrupting  
Rating  
(Amps)  
Current  
Phase  
Interrupting  
Maximum  
Voltage  
Frequency  
(Hz)  
Capacity  
(Amps)  
Maximum  
Voltage  
Frequency  
(Hz)  
Rating  
Capacity  
(Amps)  
(Amps)  
65  
277  
DC  
50/60  
50/60  
50/60  
400  
-
0.2 - 50  
0.2 - 20  
21 - 50  
0.2 - 20  
0.2 - 20  
21 - 50  
0.2 - 20  
2,000  
5,000  
2,500  
5,000  
2,500  
1,250  
2,500  
65  
250  
DC  
-
1
0.2-50  
0.2-30  
31-50  
2,000  
5,000  
2,000  
5,000  
1
50/60  
50/60  
50/60  
277  
1
250  
1
277/480  
250  
250  
250  
3Ø-Wye  
415/240  
3Ø  
0.2-30  
1
1
400  
400  
3Ø-Wye  
W9 Series  
UL/CSA (All Circuit Functions)  
W9 Series  
VDE (Circuit Function X)  
Current  
Phase  
Interrupting  
Rating  
(Amps)  
Current  
Phase  
Interrupting  
Maximum  
Voltage  
Frequency  
(Hz)  
Capacity  
(Amps)  
Maximum  
Voltage  
Frequency  
(Hz)  
Rating  
Capacity  
(Amps)  
(Amps)  
65  
277  
277/480  
250  
250  
DC  
50/60  
50/60  
400  
-
0.2 - 50  
0.2 - 50  
0.2 - 20  
0.2 - 50  
0.2 - 50  
2,000  
5,000  
5,000  
2,500  
2,500  
65  
250  
DC  
-
1
0.2-50  
0.2-30  
31-50  
2,000  
5,000  
2,000  
5,000  
1
50/60  
50/60  
50/60  
3Ø-Wye  
1
3Ø-Wye  
250  
1
415/240  
3Ø  
0.2-30  
400  
Approvals and Ratings Table 2  
UL/CSA  
VDE  
Switch  
Number  
Voltage  
50/60 Hz.  
Current  
(Amps)  
Terminals  
WxTxL  
Switch  
Number  
Voltage  
50/60 Hz.  
Current  
(Amps)  
Terminals  
WxTxL  
A
125  
10  
.093 x .020 x .250  
(2.36 x .51 x 6.40)  
V1  
V2  
V3  
250  
250  
250  
10  
5
0.1  
.110 x .020 x .280  
(2.79 x .51 x 7.11)  

与W67-X1S1-20相关器件

型号 品牌 获取价格 描述 数据表
W67-X1S3-20 TE

获取价格

Magnetic Hydraulic Circuit Breakers
W67-X1S5-20 TE

获取价格

Magnetic Hydraulic Circuit Breakers
W67-X1T1-20 TE

获取价格

Magnetic Hydraulic Circuit Breakers
W67-X1T3-20 TE

获取价格

Magnetic Hydraulic Circuit Breakers
W67-X1T5-20 TE

获取价格

Magnetic Hydraulic Circuit Breakers
W67-X2Q10-3 TE

获取价格

Magnetic Hydraulic Circuit Breakers
W67-X2Q10-5 TE

获取价格

Magnetic Hydraulic Circuit Breakers
W67-X2Q110-15 TE

获取价格

Magnetic Hydraulic Circuit Breakers
W67-X2Q110-20 TE

获取价格

Magnetic Hydraulic Circuit Breakers
W67-X2Q1-20 TE

获取价格

Magnetic Hydraulic Circuit Breakers