VPT-45A Open Frame Switching Power Supply
•
Features
·Universal AC input/ Full range
·Short circuit, overload, over-voltage
protected
·Cooling by free air convection
·Approvals: UL/CUL/TUV/CB/CE
·Fixed switching frequency at 65KHz
·Low leakage current <0.5mA
·100% full load burn-in test
·Low cost, high reliability
·2 year warranty
CH1
5V
CH2
12V
±7%
2A
CH3
-5V
DC output voltage
Output V. tolerance
Output rated current
Output min. current
Output max. current
±4%
3A
±5%
0.3A
0A
0.4A
5A
0.2A
2.5A
0.5A
Ripple & noise p-p
Line regulation
50mV
±1%
120mV
±2%
50mV
±1%
Load regulation
±3%
±4%
±1%
Rated output power
Maximum output power
40.5W
rated output power for convection
52W with 18CFM min forced air
75%
Efficiency
DC voltage adj.
Input voltage range
AC current
CH1: +10, -5%
90~264VAC 47~440Hz; 120-370VDC
1A/115V 0.7A/230V
Inrush current
cold start 20A/115V 40A/230V
<0.5mA @ 240 VAC
53~75W
Leakage current
Overload protection
type: Hiccup mode, recovers automatically after fault condition is removed
5.75~6.75VDC on CH1
Over voltage protection
Temperature coefficient
Set up, rise, hold up time
Vibration
±0.04% / °C (0~50°C) on +5V output
800ms, 20ms, 20ms
10~500Hz, 2G 10 min./1 cycle, period of 60 min. each axes
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min.
-10°C~+60% (refer to output derating curve), 20%-90% RH
-20°C~+85°C, 10%-95% RH
Withstand voltage
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
5x3x1.1 inches (127x76.2x28 mm) PCB only
0.506 lbs (0.23 Kg)
Weight
Safety standards
EMC standards
UL1950, TUV EN60950 approved
CISPR22 (EN55022), IEC1000-4-2,3,4,5 IEC1000-3-2, 3 verification
Notes:
1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
5. Output provides up to maximum current, but is related to maximum output power
6. Mounting holes M1 and M2 should be grounded for EMI purposes
V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise
customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for
customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s
published specifications. Nothing will be covered outside of standard product warranty.
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005
www.v-infinity.com
1-866-372-1258