For more information, please visit the product page
|
If your application requires forced air, view our Dc Fans
date 09/01/2017
page 1 of 6
SERIES: VOF-225A │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• up to 225 W continuous power
• -40°C to 70°C operating temperature
• industry standard foot print 2” x 4”
• low profile 1”
• power factor correction
• 12 V/0.5 A fan output
• standby power <0.5 W
• efficiency up to 94%
• long life electrolytic capacitors
output
voltage
output
current
max
output
ripple
efficiency
MODEL
power1,2
and noise3,4
max
max
typ
(Vdc)
12
(A)
(W)
(mVp-p)
(%)
VOF-225A-12
VOF-225A-15
VOF-225A-24
VOF-225A-30
VOF-225A-48
VOF-225A-58
18.75
15
225
225
225
225
225
225
120
150
240
300
480
580
92
92
93
93
94
94
15
24
9.38
7.5
30
48
4.69
3.88
58
Notes:
1. Maximum output power of 225 W with 13 CFM forced air cooling, and 120 W with natural convection cooling at 100 to 264 Vac.
2. Combined output power of main output and fan supply shall not exceed the max power rating.
3. Ripple is peak to peak with 20 MHz bandwidth and 10 µF tantalum capacitor in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. Output ripple can be more than 10% of the output voltage at -40°C.
5. All specifications are measured at Ta=25°C, nominal input voltage, and rated output load unless otherwise specified.
PART NUMBER KEY
VOF-225A - XX - X
Output Connections:
“blank” = screw type
1 = header type
Base Number
Output Voltage
cui.com