VI J00
2 5 - 1 0 0 W P C B M O U N T I N G C O M P O N E N T S
Features
•
•
•
•
•
•
•
Inputs: 10 to 400VDC
Output: 1 to 95VDC
UL, CSA, TÜV, BABT, CF, VDF
80-90% efficiency (typical)
Up to 27 watts/cubic inch
ZCS power architecture
Low noise FM control
Specifications
INPUT
Selection Table
A = INPUT VOLTAGE
B = OUTPUT VOLTAGE
Input voltage
See table
Nominal
0= 12V
Range Notes
10–20V (2)
21–32V (3)
18–36V (3)
21–56V (1)
42–60V (5)
36–76V (4)
55–100V (4)
66–160V (4)
100–200V (4)
200–400V (5)
100–375V (1)
Z = 2V
Y = 3.3V
0 = 5V
2 = 15V
N = 18.5V
3 = 24V
L = 28V
J = 36V
K = 40V
4 = 48V
H = 52V
F = 72V
D = 85V
B = 95V
OUTPUT
1= 24V
PRODUCT GRADE
Output voltage
Output power
E, C, I, M
See table
See table
1% pk-pk
0.05%
W= 24V
2= 36V
X = 5.2V
W = 5.5V
V = 5.8V
T = 6.5V
R = 7.5V
M = 10V
1 = 12V
P = 13.8V
3= 48V
N= 48V
4= 72V
Output ripple
Load regulation
Line regulation
Current limit setting
Set point accuracy
Low–high trim voltage
T= 110V
5= 150V
6= 300V
7= 150/300V
0.05%
105%–125%
0.5%
C = PRODUCT GRADE
D = OUTPUT POWER/CURRENT
50%–110%
0.5V
Size Module
Total remote sense
Compensation
V out ≥5V
Z= 25W
V out <5V
—
E= -10°C to +100°C
C= -25°C to +100°C
I= -40°C to +100°C
M= -55°C to +100°C
OPERATING
MTBF
Y = 50W
X = 75W
W = 100W
Y= 10A
X= 15A
W= 20A
>1,000,000 hrs
80%–90%
Efficiency
Baseplate operating temp. 100°C
NOTES:
Maximum Output for:
(1)
(2)
(3)
(4)
75W
100W
20A
(5)
Isolation
Input – Output: 3000V rms
5V Outputs
50W
75W
10A
50W
75W
15A
75W
100W
20A
100W*
100W
20A
ENVIRONMENTAL
>5V Outputs
<5V Outputs
Cooling
External cooling may be required, consult sales
office
*100W @ 5V (20A), 300V input only.
STANDARDS AND APPROVALS
Safety
UL1950, CSA C22.2 No.950, TÜV IEC950,
EN60950
C-Tick
AS/NZS CISPR11 Group 1 Class A
MECHANICAL
Dimensions
58x61x12.7mm
Selection Table Guide
VI - J [a] [b] - [c] [d]
Note: For RoHS version replace VI with VE.
Mechanical Drawings See page 230
228