rev.
page
page
1 of 10
date 08/2009
date
PART NUMBER: VHK200W
DESCRIPTION: chassis mount dc-dc converter
description
features
The VHK200W series of rugged DC-DC
converters are designed for high
·132-200W isolated output
·Efficiency to 87%
·RoHS Compliant
reliability applications, featuring integral
heat sink, over-temperature protection,
over-current protection and input
transient voltage protection. With an
external input fuse, the converter can
protect accidental input polarity reversal.
The wide 4:1 input range (10-36V or 18-
75V) is very useful to stabilize an input
source like batteries in various
·4:1 input range
·Regulated output
·Continuous short circuit
protection
·Metal enclosure with integrated
heatsink
·Rugged design
discharging and charging conditions.
Additionally, high efficiency, fast
response, tight regulations, remote sense
and remote On/Off control make these
converters very useful in many industrial
and communications applications.
·Over-temperature shutdown
MODEL
input voltage
output
voltage
(V dc)
output
input current
efficiency
1
nominal
(V dc)
range
(V dc)
current
(A)
no load
full load
(mA)
typ.
(%)
(mA)
100
100
100
100
100
60
VHK200W-Q24-S12
VHK200W-Q24-S15
VHK200W-Q24-S24
VHK200W-Q24-S28
VHK200W-Q24-S48
VHK200W-Q48-S12
VHK200W-Q48-S15
VHK200W-Q48-S24
VHK200W-Q48-S28
VHK200W-Q48-S48
24
24
24
24
24
48
48
48
48
48
10~36
10~36
10~36
10~36
10~36
18~75
18~75
18~75
18~75
18~75
12
15
24
28
48
12
15
24
28
48
16.7
13.3
8.3
7.14
4.2
16.7
13.3
8.3
7.14
4.2
9710
9670
9540
9521
6720
4744
4723
4716
4706
4730
84
84
84
87
87
86
86
86
87
88
60
60
60
30
notes:
1. see output derating curve (page 4)
INPUT
parameter
conditions/description
min
10
18
nom
24
48
8.8
8
9.5
8.5
17
max
36
75
units
input voltage range
V dc
V dc
V dc
V dc
V dc
V dc
V dc
V dc
under voltage lockout
24 Vin power up
24 Vin power down
24 Vin power up (48V output)
24 Vin power down (48V output)
48 Vin power up
48 Vin power down
16
remote on/off control2
input filter
section 15 in the application notes
PI type
notes:
2. add suffix “N” to the model number for negative logic on/off control
*V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-
date product information before placing orders. V-Infinity assumes no liability or responsibility for customer’s applications using V-Infinity products other than repair
or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty.
th
20050 SW 112 Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 www.v-infinity.com