xppower.com
150 Watts
VEH Series
•
•
•
•
•
•
•
Energy Efficiency Level V
CEC 2008 / EISA 2007 / ErP Compliant
No Load Input Power <0.35 W
5000 m Operating Altitude
Single Outputs from 12 V to 24 V
+60 º C Operating Temperature
Low Cost
B R A N D
Specification
Input
General
Input Voltage
Input Frequency
Input Current
Inrush Current
• 90-264 VAC, see note 1
• 47-63 Hz
• 2.0 A max at 90 VAC
• 150 A max at 230 VAC, cold start at 25 °C
Efficiency
• See table
• Level V
• 3000 VAC Input to Output,
1500 VAC Input to Ground
Negative output is connected to Ground
Energy Efficiency
Isolation
Earth Leakage Current • <500 µA at 230 VAC/50 Hz
Power Factor • >0.95 at 230 VAC and full load
No Load Input Power • <0.35 W
Switching Frequency
Power Density
MTBF
• PFC: 38-380 kHz, PWM: 47-70 kHz
3
• 4.5 W/in
• >145 kHrs to MIL STD 217F at 25 °C GB
Input Protection
• Internal T4.0A/250 V fuse in line
Environmental
Output
Operating Temperature • 0 °C to +60 °C derate linearly from 100%
load at +40 °C to 50% load at +60 °C,
Storage Temperature • -20 ˚C to +85 °C
Output Voltage
Initial Set Accuracy
Minimum Load
Hold Up Time
• See table
•
5% at 50% load
Operating Humidity
Shock
• 5% to 90% RH non-condensing
• 6 Random drops from 0.7 m with no
damage, 50 g for 20 ms in each of 3 axes
• No minimum load requirement
• 8 ms typical at 115 VAC, full load
• 3 s max
• 60 ms max
• 3% max
• 4% maxiumum deviation, recovering to
less than 1% within 500 µs for a 50%
step load change
Start Up Delay
Start Up Rise Time
Overshoot
Operating Altitude
Vibration
• 5000 m
• Operating: 10-250 Hz, 1/4 g pk-pk, 3 axes,
15 min sweep
Non Operating: 10-300 Hz, 2 g pk-pk, 3
axes, 15 min sweep
Transient Response
Storage Humidity
• 5% to 95% RH non-condensing
Line Regulation
Load Regulation
Ripple & Noise
•
0.5% max
• 3% max
EMC & Safety
• 1.5% for 12 V, 1% for 19/24 V pk-pk max,
20 MHz bandwidth (see note 2)
Emissions
• EN55022, level B conducted & radiated
• EN61000-3-2 class A,
EN61000-3-2 class C >60% load
Overvoltage Protection • See table
Overload Protection • 105-150%
Harmonic Currents
Short Circuit Protection • Continuous (hiccup/trip & restart mode
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-3-3
with auto recovery)
• EN61000-4-2, level 3 Perf Criteria A
• EN61000-4-3, 3 V/m Perf Criteria A
• EN61000-4-4, level 2 Perf Criteria A
Temperature
Coefficient
•
0.04%/°C
Surge
• EN61000-4-5, installation class 3,
Perf Criteria A
Conducted Immunity
Magnetic Field
• EN61000-4-6, level 2 Perf Criteria A
• EN61000-4-8, 3 A/m Perf Criteria A
Dips & Interruptions
• EN55024, 100% 10 ms, 30% 500 ms,
100% 5000 ms, Perf Criteria A, A, B
Safety Approvals
• EN60950-1, UL/cUL60950-1