xppower.com
20/40 Watts
VEH Series
•
•
•
•
•
•
•
Energy Efficiency Level V
CEC 2008 and EISA 2007 Compliant
Optional Inlet Connectors
Class II Versions
+60 °C Operating Temperature
Compact Dimensions
Low Cost
B R A N D
Specification
Input
General
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
• 0.5 A max VEH20
1.0 A max VEH40
• 45 A/90 A for 115 VAC/230 VAC,
cold start at 25 °C
Efficiency
• 87% typical (average of measured values
with output loads of 25%, 50%, 75%
and 100%)
Energy Efficiency
Isolation
• Level V
• 3000 VAC Input to Output
1500 VAC Input to Ground*
500 VDC Output to Ground*
*Not C2 version
• VEH20: 63 kHz typical
VEH40: 20 kHz - 60 kHz variable
Inrush Current
Earth Leakage Current • 0.75 mA at 240 VAC/50 Hz
Power Factor
• EN61000-3-2, Class A
• Internal fuse fitted in line
VEH20: T1 A, 250 V
Switching Frequency
MTBF
Input Protection
• >250 kHrs to MIL-HDBK-217F at 25 °C,GB
VEH40: T3.15 A, 250 V
No Load Input Power • <0.3 W
Environmental
Operating Temperature • 0 °C to +60 °C, derate from 100% power
at +40 °C to 50% power at +60 °C
Storage Temperature • -40 °C to +85 °C
Output
Output Voltage
Minimum Load
Hold Up Time
• See table
• No minimum load required
• VEH20: 5 ms min, VEH40: 12 ms min,
at full load & 110 VAC
• 2 s max at full load 100 VAC
• 2% deviation, recovery to within 1% of
nominal in 500 µs for 50% load change
• See table
Cooling
• Convection-cooled
• 5-95% RH, non-condensing
• 2000 m
Operating Humidity
Operating Altitude
Shock
Start Up Delay
• 10 g, 10 ms on 3 axes
Transient Response
EMC & Safety
Emissions
Regulation
• EN55022 level B conducted & radiated
• EN61000-3-2 class A
• EN61000-3-3
• EN61000-4-2 level 3 Perf criteria A
• EN61000-4-3 3 V/m Perf criteria A
• EN61000-4-4 level 2 Perf criteria A
Ripple & Noise
• 1% pk-pk max, 20 MHz bandwidth
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Overvoltage Protection • Not fitted
Overload Protection • 110-150%
Short Circuit Protection • Trip & restart (hiccup mode), auto recovery
Temperature
Coefficient
•
0.04%/°C
Surge
• EN61000-4-5 installation class 3
Perf criteria A
Conducted Immunity
Magnetic Field
• EN61000-4-6 level 2 Perf criteria A
• EN61000-4-8 1 A/m Perf criteria A
Dips & Interruptions
• EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
Safety Approvals
• EN60950-1, UL/cUL60950-1,
Approved as Limited Power Source