Performance Specifications
Table 2. Electrical Performance, LVDS Option
Parameter
Symbol
Min
Typical
Maximum
Units
Supply
Voltage1
VDD
IDD
3.135
2.375
3.3
2.5
3.465
2.625
V
V
Current (No Load)
60
mA
Frequency
Nominal Frequency2
Stability2,3, (Ordering Option)
fN
10
350.000
MHz
ppm
20, 25, 50, 100
Outputs
Output Logic Levels4
Output Logic High
Output Logic Low
VOH
VOL
1.43
1.10
1.6
V
V
0.9
Differential Output Amplitude
Differential Output Error
Offset Voltage
247
330
454
50
mV
mV
V
1.125
1.25
1.375
50
Offset Voltage Error
mV
uA
ps
Output Leakage Current
Output Rise and Fall Time4
Load
10
tR/tF
600
100 ohms differential
Duty Cycle5
45
50
55
%
Jitter (12 kHz - 20 MHz BW)155.52MHz6
Period Jitter7
RMS
фJ
фJ
0.3
0.7
ps
2.5
22
2.6
0
ps
ps
ps
ps
P/P
Random Jitter
Deterministic Jitter
Enable/Disable
Output Enabled8
Output Disabled
VIH
VIL
0.7*VDD
V
V
0.3*VDD
200
Disable Time
tD
ns
Enable/Disable Leakage Current
200
uA
Enable Pull-Up Resistor
Output Enabled
Output Disabled
33
1
KOhm
MOhm
Start-Up Time
tSU
10
ms
°C
Operating Temp. (Ordering Option)
Package Size
TOP
-10/70 or -40/85
5.0 x 7.0 x 1.8 or 5.08x7.5x2.2
mm
1. The VCC6 power supply pin should be filtered, eg, a 0.1 and 0.01uf capacitor.
2. See Standard Frequencies and Ordering Information for more information.
3. Includes calibration tolerance, operating temperature, supply voltage variations, aging and IR reflow.
4. Figure 2 defines these parameters and Figure 3 defines the test circuit.
5. Duty Cycle is defined as the On/Time Period.
6. Measured using an Agilent E5052, 155.520MHz. Please see “Typical Phase Noise and Jitter Report for the VCC6 series”.
7. Measured using a Wavecrest SIA3300C, 90K samples.
Out
Out
8. Outputs will be Enabled if Enable/Disable is left open.
50
50
6
1
5
2
4
0.01 uF
3
DC
Figure 3.
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com