VADD-55A Metal Enclosed Switching Power Supply
•
Features
·Low cost
·High reliability
·105°C output capacitor
·International AC input range
·High efficiency, low temperature rise
·Soft-start circuit, limiting AC surge current
·Short circuit, overload, battery protected
·Compact size, light weight
·100% full load burn-in test
·Built in EMI filter, low ripple noise
CH1
CH2
CH3
DC output voltage
13.8V
5V
13.4V
Output V. tolerance
Output rated current
Output current range
Ripple & noise
±1%
±3%
---
2.5A
3A
0.23A
---
0-3.5A
100mVp-p
±1%
0-4A
100mVp-p
±0.5%
±0.5%
---
Line regulation
Load regulation
DC output power
Efficiency
---
±1%
---
52.58W
71%
DC voltage adj.
Input voltage range
AC current
CH1: 12-14.5V
88~264VAC 47~63Hz; 120-370VDC
1.6A/115V 1A/230V
Inrush current
cold start 20A/115V 40A/230V
<1mA/240VAC
Leakage current
Overload protection
105%~150% / 230VAC
type: Hiccup mode, recovers automatically after fault condition is removed
CH1: 105%~135% type: pulse by pulse
Over voltage protection
DC alarm signal (optional)
AC fail CH1 PIN2
battery low under charge voltage 82.5% ± 2% CN1 PIN1
normal 0.8V max. abnormal 5V±0.5V
Temperature coefficient
Set up, rise, hold up time
Vibration
±0.03% / °C (0~50°C) on CH1 output
1.6s, 50ms, 16ms/115VAC 800ms, 50ms, 60ms / 230VAC
10~500Hz, 2G 10 min./1 cycle, period of 60 min. each axes
I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC, for 1 min.
I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min.
-10°C~+60% (refer to output derating curve), 20%-90% RH
-20°C~+85°C, 10%-95% RH
Withstand voltage
Isolation resistance
Working temp., humidity
Storage temp., humidity
Dimensions
6.36x3.88x1.52 inches (161.54x98.55x38.6mm) Case: 901
1.25lbs (0.57 Kgs)
Weight
Safety standards
EMC standards
meets IEC950 requirements
meets CISPR22 (EN55022) class B, EN61000-4,2,3,4,5,6,8,11,
EN61000-3-2, -3 verification
Notes:
1. All parameters are specified at 230VAC input, rated load, 25°C 70% ambient
2. Tolerance includes set up tolerance, line regulation, load regulation
3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor
4. Line regulation is measured from low line to high line at rated load
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load
6. Each output provides up to maximum current, but total load can not exceed maximum output power
7. CH2 Bat. charger voltage at no load, rated current at Bat. V=11V/22V
V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise
customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for
customer’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s
published specifications. Nothing will be covered outside of standard product warranty.
V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005