CONTROL FUNCTIONS - PC PIN  
Module Enable/Disable  
Module Alarm  
The module may be disabled by pulling PC below 2.3V with  
respect to the –Input. This may be done with an open collector  
transistor, relay, or optocoupler. Multiple converters may be  
disabled with a single transistor or relay either directly or via  
“OR’ing” diodes. See Figure 1.  
The module contains “watchdog” circuitry which monitors  
input voltage, operating temperature and internal operating  
parameters. In the event that any of these parameters are  
outside of their allowable operating range, the module will shut  
down and PC will go low. PC will periodically go high and the  
module will check to see if the fault (as an example,  
overtemperature) has cleared. If the fault has not been cleared,  
PC will go low again and the cycle will restart. The SC pin will  
go low in the event of a fault and return to its normal state after  
the fault has been cleared. See Figures 2 and 4.  
Primary Auxiliary Supply  
At 5.7V, PC can source up to 1.5mA. In the example shown in  
Figure 3, PC powers a module enabled LED.  
Input Undervoltage  
Input Overvoltage  
+Out  
+In  
PC  
+In  
PC  
Overtemperature  
+Out  
Auto  
Restart  
Module Faults  
SW1  
+S  
SC  
–S  
+S  
SC  
–S  
2-20ms typ.  
50  
f (V )  
IN  
SW1, 2, & 3  
shown in  
"Fault" position  
1K  
SW2  
SW3  
PR  
–In  
Disable  
PR  
–In  
5.7Vdc  
(0-3mA)  
1.23  
Vdc  
–Out  
–Out  
6K  
Disable = PC <2.3V  
Figure 1—Module enable/disable.  
Figure 2—PC/SC module alarm logic.  
+In  
PC  
+Out  
Fault  
PC  
40µs typ.  
5.7V  
+S  
SC  
–S  
4k  
"Module  
PR  
–In  
Enabled"  
1.23V  
2-20ms typ.  
SC  
–Out  
Figure 3—LED on-state indicator.  
Figure 4—PC/SC module alarm timing.  
Optocoupler  
+In  
PC  
+In  
PC  
+Out  
+Out  
+S  
SC  
–S  
+S  
SC  
–S  
Alarm  
4kW  
PR  
–In  
PR  
–In  
1.00V  
–Out  
–Out  
Figure 5—Isolated on-state indicator.  
Figure 6—Secondary side on-state indicator.  
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715  
375V Mini Family  
Rev. 6.4  
Page 4 of 8  
Set your site on VICOR at www.vicorpower.com  

与V375B48H300AN3相关器件

型号 品牌 描述 获取价格 数据表
V375B48H300AS VICOR DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid

获取价格

V375B48H300AS2 VICOR DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid

获取价格

V375B48H300AS3 VICOR DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid

获取价格

V375B48H300B VICOR 375Vin / 48Vout / 300Watts DC-DC Converter Module

获取价格

V375B48H300B2 VICOR DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, PACKAGE-9

获取价格

V375B48H300B3 VICOR DC-DC Regulated Power Supply Module, 1 Output, 300W, Hybrid, PACKAGE-9

获取价格