5秒后页面跳转
V23234-B1001-X010 PDF预览

V23234-B1001-X010

更新时间: 2024-11-29 12:01:15
品牌 Logo 应用领域
MACOM 继电器功率继电器
页数 文件大小 规格书
4页 876K
描述
Power Relay B Plug-in Mini ISO Relays Automotive Relays

V23234-B1001-X010 数据手册

 浏览型号V23234-B1001-X010的Datasheet PDF文件第2页浏览型号V23234-B1001-X010的Datasheet PDF文件第3页浏览型号V23234-B1001-X010的Datasheet PDF文件第4页 
Automotive Relays  
Plug-in Mini ISO Relays  
Power Relay B  
n
n
n
Pin assignment similar to ISO 7588 part 1  
Plug-in terminals  
Customized versions on request  
– 24VDC versions with contact gap >0.8mm  
– Integrated components (e.g. resistor, diode)  
– Customized marking/color  
– Special covers (e.g. notches, release features, brackets)  
– Various contact arrangements and materials  
Typical applications  
Cross carline up to 35A for example: rear window defogger, battery  
disconnection, power distribution (clamp 15)  
F234_fcw1_bw  
Contact Data  
Contact arrangement  
1 A  
1 form A,  
1 NO  
1 A  
1 form A,  
1 NO  
1 C  
1 form C,  
1 CO  
1 C  
1 form C,  
1 CO  
Rated voltage  
12VDC  
24VDC  
12VDC  
24VDC  
Coil Data  
Limiting continuous current  
form A/form B (NO/NC)  
23°C  
Rated coil voltage  
12/24VDC  
Coil  
50A  
35A  
15A  
50A  
35A  
15A  
50/35A  
35/25A  
15/10A  
50/35A  
35/25A  
15/10A  
Coil versions, DC coil  
Coil  
code  
85°C  
Rated  
voltage  
VDC  
12  
12  
24  
Operate  
voltage  
VDC  
8
6.5  
16  
Release  
voltage  
VDC  
1.5  
1
3
Rated coil  
125°C  
resistance 5) power 5)  
Limiting making current1)  
Ω 10ꢀ  
85  
75  
W
A/B (NO/NC)  
Limiting breaking current,  
A/B (NO/NC)  
120A  
30A  
120A  
20A  
120/45A  
30/20A  
120/45A  
20/10A  
001  
002  
004  
1.7  
1.9  
2.3  
255  
5) Without components in parallel.  
All figures are given for coil without pre-energization, at ambient temperature +23°C.  
Limiting short-time current  
overload current, ISO 8820-3 2)  
1.35 x 35A, 1800s  
2.00 x 35A, 5s  
3.50 x 35A, 0.5s  
6.00 x 35A, 0.1s  
24VDC for 5min,  
Insulation Data  
Initial dielectric strength  
Jump start test, ISO 16750-1  
between open contacts  
between contact and coil  
between adjacent contacts  
Load dump test  
ISO 7637-1 (12VDC), test pulse 5  
ISO 7637-2 (24VDC), test pulse 5  
500Vrms  
500Vrms  
500Vrms  
conducting nominal current at 23°C  
Silver based  
Contact material  
Min. recommended contact load3)  
Initial voltage drop, at 10A, typ./max.  
1A at 5VDC  
Vs=+86.5VDC  
Vs=+200VDC  
form A (NO)  
form B (NC)  
15/300mV 15/300mV 15/300mV 15/300mV  
-
-
20/300mV 20/300mV  
6 ops./min (0.1Hz)  
10/10ms4)  
Frequency of operation, at nominal load  
Operate/release time typ.  
Other Data  
Electrical endurance, ops.  
EU RoHS/ELV compliance  
Protection to heat and fire according UL94  
Ambient temperature  
compliant  
HB or better6)  
-40 to 125°C  
resistive load, A (NO) >2.5x105  
>2.5x105  
20A,  
>2.5x105  
30A,  
>2.5x105  
20A,  
30A,  
14VDC  
28VDC  
-
14VDC  
28VDC  
>2.5x105  
10A,  
Climatic cycling with condensation,  
EN ISO 6988  
Temperature cycling,  
IEC 60068-2-14, Nb  
Damp heat cyclic,  
resistive load, B (NC)  
Mechanical endurance  
-
>1x105  
6 cycles, storage 8/16h  
20A,  
14VDC  
28VDC  
10 cycles, -40/+85°C (5°C/min)  
typ. 1x106 ops.  
1) The values apply to a resistive or inductive load with suitable spark suppression and  
at maximum 14VDC for 12VDC or 28VDC for 24VDC load voltages. For a load current  
duration of maximum 3s for a make/break ratio of 1:10.  
2) Current and time are compatible with circuit protection by a typical automotive fuse.  
Relay will make, carry and break the specified current.  
3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at  
http://relays.te.com/appnotes/  
4) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay  
coil increases the release time and reduces the lifetime caused by increased erosion  
and/or higher risk of contact tack welding.  
IEC 60068-2-30, Db, Variant 1  
6 cycles, upper air temp. 55°C  
Damp heat constant, IEC 60068-2-3, Ca  
Category of environmental protection,  
IEC 61810  
Degree of protection, IEC 60529  
Corrosive gas  
IEC 60068-2-42  
IEC 60068-2-43  
Vibration resistance (functional)  
IEC 60068-2-6 (sine sweep)  
Shock resistance (functional)  
IEC 60068-2-27 (half sine)  
Drop test, free fall, IEC 60068-2-32  
56 days  
RT I – dustproof  
IP54  
10 2cm3/m3 SO2, 10 days  
1 0.3cm3/m3 H2S, 10 days  
10 to 500Hz, min. 5g7)  
11ms, min. 20g7)  
1m onto concrete  
1
06-2011, Rev. 0611  
Datasheets and product specification ac-  
cording to IEC 61810-1 and to be used only  
together with the ‘Definitions’ section.  
Datasheets and product data is subject to the  
terms of the disclaimer and all chapters of  
the ‘Definitions’ section, available at  
http://relays.te.com/definitions  
Datasheets, product data, ‘Definitions’ sec-  
tion, application notes and all specifications  
are subject to change.  
www.te.com  
© 2011 Tyco Electronics Corporation,  
a TE Connectivity Ltd. company.  

与V23234-B1001-X010相关器件

型号 品牌 获取价格 描述 数据表
V23234-C0001-X003 MACOM

获取价格

Power Relay B Plug-in Mini ISO Relays Automotive Relays
V23234-C0001-X006 MACOM

获取价格

Power Relay B Plug-in Mini ISO Relays Automotive Relays
V23234-C0004-X018 MACOM

获取价格

Power Relay B Plug-in Mini ISO Relays Automotive Relays
V23234-C0004-X020 MACOM

获取价格

Power Relay B Plug-in Mini ISO Relays Automotive Relays
V23234-C1001-X005 MACOM

获取价格

Power Relay B Plug-in Mini ISO Relays Automotive Relays
V23234-C1004-X017 MACOM

获取价格

Power Relay B Plug-in Mini ISO Relays Automotive Relays
V23234-C1004-X085 MACOM

获取价格

Power Relay B Plug-in Mini ISO Relays Automotive Relays
V23234-K1001-X024 MACOM

获取价格

Power Relay B Plug-in Mini ISO Relays Automotive Relays
V23333 MACOM

获取价格

Connectors for Mini ISO Relays Connectors (Production Europe only)
V23333-Z0001-A007 MACOM

获取价格

Connectors for Mini ISO Relays Connectors (Production Europe only)