Plug-in Maxi ISO Relays
Power Relay F7
n
n
Pin assignment similar to ISO 7588 part 1
Customized versions on request
– 24VDC versions with contact gap >0.8mm
– Integrated components (e.g. resistor, diode)
– Customized marking/color
– Special covers (e.g. notches, release features, brackets)
Typical applications
Cross carline up to 70A for example: ABS control, cooling fan, energy
management, engine control, glow plug, heated front screen, ignition,
lamps: front, rear, fog light, main switch/supply relay.
F134J_a_bw
Contact Data
Contact Data (continued)
Contact arrangement
1 form A,
1 NO
-
1 form A,
1 NO
-
1 form A,
1 NO
Mechanical endurance
>1x107ops.
1) Special high performance 24VDC version with contact gap >0.8mm, part number
V23134-A0056-X408 (see part number table).
2) The values apply to a resistive or inductive load with suitable spark suppression and
at maximum 14VDC for 12VDC or 28VDC for 24VDC load voltages. For a load current
duration of maximum 3s for a make/break ratio of 1:10.
3) Current and time are compatible with circuit protection by a typical automotive fuse.
Relay will make, carry and break the specified current.
4) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
Contact gap
Rated voltage
Limiting continuous current
23°C
85°C
>0.8mm
12VDC
24VDC
24VDC1)
70A
50A
30A
240A
70A
70A
50A
30A
240A
25A
70A
50A
30A
240A
40A
125°C
Limiting making current2)
Limiting breaking current
Limiting short-time current
overload current, ISO 8820-33)
5) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay
coil increases the release time and reduces the lifetime caused by increased erosion
and/or higher risk of contact tack welding.
1.35 x 50A, 1800s
2.00 x 50A, 5s
3.50 x 50A, 0.5s
6.00 x 50A, 0.2s
24VDC for 5min,
Coil Data
Rated coil voltage
12VDC, 24VDC
Jump start test, ISO 16750-1
conducting nominal current at 23°C
Silver based
Coil versions, DC coil
Coil
code
Contact material
Rated
voltage
VDC
12
24
24
Operate
voltage
VDC
7.2
14.4
16.0
14.4
Release
Coil
resistance6)
Ω 10ꢀ
90
Rated coil
power6)
W
Min. recommended contact load4)
Initial voltage drop,
1A at 5VDC
voltage
VDC
1.6
form A (NO) contact at 10A, typ./max.
Frequency of operation at nominal load
Operate/release time typ.
Electrical endurance
resistive load at 14VDC
10/300mV
6 ops./min (0.1Hz)
7/2ms5)
052
053
056
065
1.6
1.8
2.1
2.0
3.2
4.0
2.4
324
268
288
24
>1x105 ops.
-
-
-
6) Without components in parallel.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
70A
>2x105 ops.
-
50A
-
resistive load at 28VDC
>1x105ops. >1x105 ops.
25A 50A
Max. DC load breaking capacity
Coil operating range
TEVF4_OVR1
ECR0629-N
Load limit curve: safe shutdown, no stationary arc/make contact.
Load limit curve measured with low inductive resistors verified for 1000 switching events.
Does not take into account the temperature rise due to the contact current
E = pre-energization.
1
04-2013, Rev. 0413
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog, product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
www.te.com
© 2013 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.