Automotive Relays
PCB Single Relays
Power Relay K (Open – Sealed)
n
n
n
n
Limiting continuous current 45A
Wide voltage range
24VDC coil versions available
For high current version refer to Power Relay K-S
Typical applications
ABS control, blower fans, car alarm, cooling fan, engine control, fuel pump,
hazard warning signal, heated front screen, heated rear screen, ignition,
lamps front/rear/fog light, interior lights, main switch/supply relay, seat
control, seatbelt pretensioner, sun roof, turn signal, valves, window lifter,
wiper control.
Contact Data
Typical applications
Resistive/inductive
loads
1 form A, 1 NO
12VDC
Resistive/inductive
loads
1 form C, 1 CO
12VDC
Indicator lamps
Headlights,
capacitive loads
1 form A, 1 NO
12VDC
Headlights
capacitive loads
1 form C, 1 CO
12VDC
Contact arrangement
Rated voltage
1 form A, 1 NO
12VDC
A/B (NO/NC)
45/30A
A/B (NO/NC)
40/25A
Rated current
Limiting continuous current
23°C
45A
30A
40A
45A
30A
100A
60A
AgNi0.15
45/30A
30/25A
100/30A
60/30A
30A
25A
40A
25A
180A
60A
40/25A
25/20A
180/60A
60/30A
AgSnO2
85°C
Limiting making current1)
Limiting breaking current2)
Contact material
120A3)
60A
AgNi0.15
AgSnO2
AgSnO2
Min. recommended contact load
Initial voltage drop, at 10A, typ./max.
Operate/release time
Electrical endurance
1A at 5VDC4)
20/300mV
typ. 5/3ms5)
>2x105 ops.
at 13.5VDC, 40A
>2x105 ops.
at 13.5VDC, 40A
>107 ops.
>2.2x106 ops.
up to 8x21W
>105 ops.
up to 4x60W
>105 ops.
up to 4x60W
Mechanical endurance, DC coil
1) The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5VDC for 12VDC or 27VDC for 24VDC load voltages.
2) For a load current duration of maximum 3s for a make/break ratio of 1:10.
3) Corresponds to a peak inrush current on initial actuation (cold filament).
4) See chapter Diagnostics of Relays in our Application Notes or consult the internet at http://relays.te.com/appnotes/
5) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay coil increases the release time and reduces the lifetime caused by increased erosion and/or higher
risk of contact tack welding.
Max. DC load breaking capacity
TE0556-E
Load limit curve 1: arc extinguishes, during transit time (changeover contact).
Load limit curve 2: safe shutdown, no stationary arc (make contact).
Load limit curves measured with low inductive resistors verified for 1000 switching events.
1
06-2011, Rev. 0611
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
www.te.com