US2A thru US2M
SSUURRFFAACCEE MMOOUUNNTT RREEVVEERRSSEE VVOOLLTTAAGGEE 5500 TTOO 11000000 VVOOLLTTSS
ULTRA FAST RECTIFIERS FORWARD CURRENT - 2.0 AMPERES
SMA/DO-214AC
.055(1.40)
.062(1.60)
.098(2.50)
.114(2.90)
.157(4.00)
.181(4.60)
.006(.152)
.012(.305)
.078(2.00)
.096(2.44)
.030(0.76)
.060(1.52)
.004(.102)
.008(.203)
.188(4.80)
.208(5.28)
Dimensions in inches and (millimeters)
FEATURES
MECHANICAL DATA
For surface mounted applications
Low profile package
Case JEDEC DO-214AC molded plastic
Terminals Solder plated, solderable per
MIL-STD-750, Method 2026
Built-in strain relief
Easy pick and place
Polarity Indicated by cathode band
Standard Packaging 12mm tape (ELA-481)
Weight 0.064grams
Ultrafast recovery times for high efficiency
Plastic package has Underwriters Laboratory
Flammability classification 94V-0
Glass passivated junction
High temperature soldering
o
260 C/10seconds at terminals
MAXIMUM RATIXGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature unless otherwise specified
Single phase, half wave, 60Hz, resistive or inductive load
For capacitive load, derate current by 20%
SYMBOL US2A
US2D US2F US2G
US2M UNITS
US2J US2K
US2B
100
70
Maximum Repetitive Peak Reverse Voltage
Maximum RMS Voltage
Volts
Volts
Volts
Amps
VRRM
VRMS
VDC
I(AV)
50
35
50
200
140
200
300
210
300
400
280
400
600
420
600
800 1000
560
700
800 1000
Maximum DC Blocking Voltage
100
0
Maximum Average Forward Rectified Current @ TL =100 C
2.0
Peak Forward Surge Current 8.3ms Single Half Sine-Wave
Amps
Volts
A
IFSM
VF
IR
50
0
Superimposed on Rated Load (JEDEC Method) TA=55 C
MaximumInstantaneous Forward Voltage at 2.0A DC
1.0
1.3
1.7
0
Maximum DC Reverse Current @TA=25 C
5.0
0
at Rated DC Blocking Voltage @TA=100 C
100
Typical Junctionn Capacitance (NOTE 2)
pF
nS
CJ
TRR
TJ
50
50
30
75
0
Maximum Reverse Recovery Time (NOTE 1) TJ=25 C
0
Maximum Thermal Resistance (NOTE 3)
-55 to +150
C
TJ
0
Operating and Storage Temperature Range
-55 to +150
C
TSTG
NOTES
1. Rverse Recovery Test Condibons IF=5A, IR=1A, lRR=0.25A
2. Measured at 1 MHz and applied reverse Voltag of 4.0VDC
3. Measured on P.C.Board with 0.2 x0.2 (5mmX5mm) Copper Pad Area.
www.paceleader.tw
1