150W U-Bracket Single Output with PFC Function
ULP-150 series
Features :
Universal AC input / Full range(up to 295VAC)
Built in active PFC compliance to EN61000-3-2 class C
Constant Voltage design
High efficiency up to 93%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Half encapsulated
U-bracket low profile:33mm
ZVS technology to reduce power dissipation
Suitable for built-in type LED applications
3 years warranty
SPECIFICATION
MODEL
ULP-150-24
ULP-150-36
ULP-150-15
ULP-150-48
ULP-150-12
DC VOLTAGE
15V
24V
36V
48V
12V
RATED CURRENT
10A
6.3A
4.2A
3.2A
12.5A
CURRENT RANGE
0 ~ 10A
150W
0 ~ 6.3A
151.2W
150mVp-p
21.6~26.4V
2.0%
0 ~ 4.2A
151.2W
250mVp-p
32.4~39.6V
2.0%
0 ~ 3.2A
153.6W
250mVp-p
43.2~52.8V
2.0%
0 ~ 12.5A
150W
RATED POWER
RIPPLE & NOISE (max.) Note.2
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
150mVp-p
13.5~16.5V
2.0%
100mVp-p
11.0~13.2V
OUTPUT
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
SETUP, RISE TIME
1.0%
1.0%
1.0%
1.0%
1.0%
2000ms, 100ms/230VAC
3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC
16ms/115VAC at full load
127 ~ 417VDC
VOLTAGE RANGE
Note.4 90 ~ 295VAC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
47 ~ 63Hz
PF 0.98/115VAC
PF>0.96/230VAC PF 0.94/277VAC at full load
91.5% 93%
1A/230VAC 0.7A/277VAC
INPUT
93%
93%
91.5%
2A/115VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
Cold start 65A/230VAC
<0.75mA / 277VAC
130~185% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
OVER VOLTAGE
PROTECTION
17 ~ 21V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
95 (RTH2)
26.7 ~ 32.4V
41.4 ~ 48.6V
53 ~ 64.8V
13.6 ~ 16.3V
5
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-30 ~ +70 (Refer to "Derating Curve")
WORKING TEMP.
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 60
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
Design refer to EN61347-2-13,IEC61347-2-13,UL8750
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
SAFETY STANDARDS
WITHSTAND VOLTAGE Note.6
ISOLATION RESISTANCE
EMC EMISSION
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH
EMC
(Note 5)
Compliance to EN55015, EN61000-3-2 Class C( 60% load),EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
EMC IMMUNITY
MTBF
216.3K hrs min. MIL-HDBK-217F (25
215*67.4*33mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
0.67kg; 24PCS/17.5kg/0.65CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
6. Please remove the component D1 before conducted Hipot test.
File Name:ULP-150-SPEC 2011-08-11