Multilayer Ceramic Capacitors  
Approval Sheet  
No.  
Item  
Test Condition  
Requirements  
12. Temperature  
Cycle  
* Conduct the five cycles according to the temperatures and  
time.  
* No remarkable damage.  
* Cap changewithin ±2.5or ±0.25pF whichever is larger.  
Step  
Temp. (°C)  
Min. operating temp. +0/-3  
Room temp.  
Time (min.)  
30±3  
* Q/D.F., I.R. and dielectric strength: To meet initial requirements.  
1
2
3
4
2~3  
Max. operating temp. +3/-0  
Room temp.  
30±3  
2~3  
* Cap. / DF(Q) / I.R. Measurement to be made after de-aging at  
150°C for 1hr then set for 24±2 hrs at room temp.  
* Test temp.: 40±2°C  
13. Humidity  
(Damp Heat)  
Steady State  
* No remarkable damage.  
* Humidity: 90~95% RH  
* Cap change: within ±5.0% or ±0.5pF whichever is larger.  
* Q/D.F. value: Q200+10C  
* Test time: 500+24/-0hrs.  
* Cap. / DF(Q) / I.R. Measurement to be made after de-aging at  
150°C for 1hr then set for 24±2 hrs at room temp.  
* Test temp.: 40±2°C  
* I.R.: 1G.  
14. Humidity  
(Damp Heat)  
Load  
* No remarkable damage.  
* Humidity: 90~95%RH  
* Cap change: within ±7.5% or ±0.75pF whichever is larger.  
* Q/D.F. value: Q100+10/3C  
* Test time: 500+24/-0 hrs.  
* To apply voltagerated voltage  
* I.R.: 500M.  
* Cap. / DF(Q) / I.R. Measurement to be made after de-aging at  
150°C for 1hr then set for 24±2 hrs at room temp.  
* Test temp.: 125±3°C  
15. High  
Temperature  
Load  
* No remarkable damage.  
* To apply voltage: 200% of rated voltage.  
* Test time: 2000+24/-0 hrs.  
* Cap change: within ±3.0% or ±0.3pF whichever is larger.  
* Q/D.F. value: Q200+10C  
(Endurance)  
* Cap. / DF(Q) / I.R. Measurement to be made after de-aging at * I.R.: 1G.  
150°C for 1hr then set for 24±2 hrs at room temp  
The ESR should be measured at room temperature and tested  
at frequency 1±0.1 GHz.  
16. ESR  
0402  
0.1pFCap1pF:< 350m/pF  
1pF<Cap5pF:< 300mΩ  
5pF<Cap100pF:< 250mΩ  
Page 6 of 8  
ASC_Microwave_with_Narrow_Tol_(UF)  
Jul. 2019  

与UF15N0R5Q250CG相关器件

型号 品牌 描述 获取价格 数据表
UF15N0R5Q250CT WALSIN Microwave MLCC with Narrow-Tolerance