UCRETE UD200
Heavy duty polyurethane concrete flooring system
Surface Resistivity (BS2050)
Density (BS6319:Part 5)
Water Adsorption (CP.BM 2/67/2)
Surface Spread of Flame
(BS476:Part 7)
: 3x10-4ohms
: 2090 kg/m3
: 0 ml
DESCRIPTION
Ucrete UD200 is a single layer, seamless, solvent-free,
polyurethane flooring system. It has a textured matt
: Class 2
finish possessing
a
wide spectrum of chemical
resistance; withstands abrasive wear; has high impact
resistance and withstands direct steam impact.
PROPERTIES
RECOMMENDED FOR
Colours
: Yellow ~ RAL 1004
Cream ~ RAL 1014
Orange ~ RAL 2010
Red ~ RAL 3001
Green ~ RAL 6010
Ucrete UD200 is recommended for conditions requiring
the maximum of chemical resistance, health and safety
and where thermal situations arise, from cool rooms to
hot environments.
Grey
~ RAL 7037
Specific applications include:
Thickness
: 5 to 9 mm.
•
•
•
•
•
•
meat, fish and poultry processing
food and beverage production
dairies, cheese and milk products
cold rooms, chillers and freezers
pharmaceutical production
chemical plants
Service temperatures
at 9 mm
: 120°C max. & -40°C
: 70°C max. & -20°C
at 6 mm
APPLICATION
Surface Preparation
Concrete shall be clean, structurally sound and free
from foreign materials, contaminants, oily products and
other debris. Concrete surfaces shall be ‘visibly dry’ with
no standing water. The minimum tensile (pull-off)
strength shall be 1.5N/mm² and concrete shall have
cured for at least 5 days. Concrete substrates shall
incorporate a continuous waterproofing membrane.
FEATURES AND BENEFITS
Expert
Installed only by trained and approved
application
specialist contractors.
Fast
Can be applied to 6-day-old concrete
Concrete design shall allow provisions for movement
joints, as required. In addition, provision shall be made
for induced joints to allow any shrinkage of the concrete
to occur along defined planes.
All laitance shall be removed. All imperfections such as
holes and cracks shall be repaired and levelled with the
mean level of the surface. For repairing surface
uneveness, EMACO® concrete repair systems shall be
used.
application/r or
2
day old polymer screeds.
apid access
Short curing time and 8 hours access
to foot traffic; 20 hours for vehicles.
Hygienic/
safe
Slip resistant, non-tainting, non-
dusting, monolithic (minimum joints),
easy to maintain, microbiologically
inert.
Durable/long
life
Wide chemical resistance, wear and
impact resistant, resists temperatures
The whole surface shall be enclosed or impact shot
blasted, surface planed, ground or high-pressure water
jetted. All high spots shall be removed. Surfaces shall
be rendered ‘visibly dry’ by heat or mechanical means.
from -40°C to 120°C at
9 mm
thickness; 25 years of international
use.
Remove all loose material and dust by vacuum or
Prepacked
Preweighed/ prepacked for immediate
use; batch to-batch colour matched
for consistency.
mechanical means.
Priming
Ucrete UD200 shall be applied to a cured scratch coat
of Ucrete MF of 1 mm nominal thickness.
TYPICAL PERFORMANCE DATA
(After 28 days @ 20°C)
Placing
Compressive Strength (BS6319:Part 2) : 58 N/mm2
Ucrete UD200 shall be mixed and applied only by
specialist flooring contractors who have been trained in
the correct application procedures.
Flexural Strength (ISO178)
: 14 N/mm2
Dynamic E-Modulus (ASTM C597-83) : 19500 N/mm2
Tensile Strength (ISO R527)
Concrete Adhesion (BS6319:Part 2)
Abrasion Resistance (Taber H22)
Coeff. Thermal Expansion
(ASTM C531)
: 6 N/mm2
CURING
: concrete fails
: 1390mg
At 30°C, foot traffic access in 8 hours; vehicular traffic in
16 hours. At 20°C, foot traffic access in 12 hours;
vehicular traffic in 24 hours. Full cure at 28 days.
: 2.4x10-5 °C-1
Thermal Conductivity (BS874)
: 1.1W/m°C
Page 1 of 2