UCC28710, UCC28711
UCC28712, UCC28713
UCC28714, UCC28715
www.ti.com
SLUSB86 –NOVEMBER 2012
ELECTRICAL CHARACTERISTICS (continued)
over operating free-air temperature range, VVDD = 25 V, HV = open, RCBC(NTC) = open, TA = -40°C to 125°C, TA = TJ
(unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
PROTECTION
VOVP
Over-voltage threshold
Over-current threshold
VS line-sense run current
At VS input, TJ = 25°C(2)
4.55
4.60
4.71
V
VOCP
At CS input
1.4
190
70
1.5
225
80
1.6
275
100
3.05
IVSL(run)
Current out of VS pin increasing
Current out of VS pin decreasing
IVSL(run) / IVSL(stop)
µA
IVSL(stop) VS line-sense stop current
KVSL
VS line sense ratio
2.45
2.80
165
A/A
°C
TJ(stop)
Thermal shut-down temperature
Internal junction temperature
CABLE COMPENSATION
UCC28710
UCC28714
UCC28715
Cable compensation maximum
voltage
VCBC(max)
Voltage at CBC at full load
2.9
-55
3.2
-15
3.5
25
V
UCC28710
UCC28714
UCC28715
VCBC = open, change in VS
regulating level at full load
VCVS(min) Compensation at VS
mV
UCC28710
UCC28714
UCC28715
VCBC = 0 V, change in VS regulating
level at full load
VCVS(max) Maximum compensation at VS
275
-55
320
375
25
UCC28711
UCC28712
UCC28713
-15
103
206
Change in VS regulating level at full
load
VCVS
Compensation at VS
mV
NTC INPUT
VNTCTH NTC shut-down threshold
UCC28711
UCC28712
UCC28713
Fault UVLO cycle when below this
threshold
0.90
90
0.95
105
1.00
125
V
UCC28711
UCC28712
UCC28713
INTC
NTC pull-up current
Current out of pin
µA
(2) The regulating level at VS decreases with temperature by 0.8 mV/˚C. This compensation is included to reduce the power supply output
voltage variance over temperature.
Copyright © 2012, Texas Instruments Incorporated
Submit Documentation Feedback
5
Product Folder Links: UCC28710, UCC28711 UCC28712, UCC28713 UCC28714, UCC28715