Ultrasonic
Diffuse, Analogue and Digital Output
Types UA30EAD......TI
• Cylindrical M30 Stainless Steel INOX
AISI 316L housing
• Sensing distance: 350-3500 mm
• Power supply: 12 (15) to 30 VDC
• Outputs: 0-10 VDC or 4-20 mA and one switching
output NPN or PNP.
• Linearity error 1%
• Repeatability 1%
• Beam angle. ±±7
• Protection: Short-circuit, reverse polarity and
overvoltage
• Protection degree IP 6±
• 2 m cable or M12 plug
Product Description
Ordering Key
UA30EAD35NGM1TI
A family of diffuse ultrason-
ic sensors in Stainless steel
housing and with sensing
range from 350-3500 mm
with a resolution as low as
2.0 mm.
forms a windows detection. Ultrasonic sensor
The sensor is the ideal choice Housing style
for distance measurement, Housing size
level measurement, diameter Housing material
measurement or loop control. Housing length
Due to use of microproces- Detection principle
sor control the digital filtering Sensing distance
makes the sensor immune to Output type
most electromagnetic inter- Output configuration
The sensor contains both an
analogue and a digital output.
The output is either 0-10V or
4-20 mA and the digital output
NPN or PNP, NO or NC which
ferences.
Connection
Teach-in
Type Selection
Housing
diameter
Connec-
tion
Rated operating
dist. (Sn)
Analog
Output
Digital output
NPN/PNP
Ordering no.
M30
M30
M30
M30
M30
M30
M30
M30
Plug M12
Cable
Plug M12
Cable
Plug M12
Cable
Plug M12
Cable
350-3500 mm
350-3500 mm
350-3500 mm
350-3500 mm
350-3500 mm
350-3500 mm
350-3500 mm
350-3500 mm
4-20 mA
4-20 mA
0-10 V
NPN
NPN
NPN
NPN
PNP
PNP
PNP
PNP
UA 30 EAD 35 NG M1 TI
UA 30 EAD 35 NG TI
UA 30 EAD 35 NK M1 TI
UA 30 EAD 35 NK TI
UA 30 EAD 35 PG M1 TI
UA 30 EAD 35 PG TI
UA 30 EAD 35 PK M1 TI
UA 30 EAD 35 PK TI
0-10 V
4-20 mA
4-20 mA
0-10 V
0-10 V
Specifications
Rated operating distance (Sn) Reference target: 1 mm
metal rolled finish, size
Rated operational voltage (UB)
NG or PG versions
NK or PK versions
12 to 30 VDC
15 to 30 VDC
(ripple included)
400 x 400 mm.
350 - 3500 mm
Blind zone
≤ 350 mm
Ripple (Urpp
)
≤ 5%
Repeatability
Linearity error
Beam angle
Sensitivity
Push-button
1%
1%
7ꢀ
No-load supply current (Io)
50 mA @ UB max
Output current continuous
digital output (Ie)
Max. load capacity 100 nF
100 mA
Output current short-time
digital output (I)
Max. load capacity 100 nF
P1 (longest setpoint)
P2 (shortest setpoint)
2 mm
100 mA
0.5 mA
10 μA
Resolution
Minimum operational current
digital output (Im)
OFF-state current digital
output (Ir)
Temperature drift
Temperature compensation Yes
Hysteresis (H)
0.1%/ꢀC @ -20ꢀ to +70ꢀ C
Min. 1%
Specifications are subject to change without notice (06.06.2017)