TMCP
Vishay Polytech
www.vishay.com
POWER DISSIPATION
CASE CODE
MAXIMUM PERMISSIBLE POWER DISSIPATION AT +25 °C (W) IN FREE AIR
0.064
P
STANDARD PACKAGING QUANTITY
CASE CODE
UNITS PER 7" REEL
3000
P
PERFORMANCE CHARACTERISTICS
ITEM
CONDITION
POST TEST PERFORMANCE
Specified
initial value
-55 °C
+85 °C
+125 °C
Capacitance
change
-
-20 ꢀ to 0 ꢀ 0 ꢀ to +20 ꢀ 0 ꢀ to +20 ꢀ
6
10
12
14
16
24
60
8
10
12
14
16
24
40
8
10
12
14
22
30
Temperature
Measure the specified characteristics in
characteristics each stage
10
12
20
30
Dissipation
factor (ꢀ)
Refer to
Standard
Ratings
table
1000 ꢀ
specified
intial value
or less
1250 ꢀ
specified
intial value
or less
Leakage
current
-
Solder dip:
Capacitance change
Dissipation factor
Leakage current
Within 20 ꢀ of initial value
Initial specified value or less
Initial specified value or less
Within 20 ꢀ of initial value
Solder heat
resistance
260 °C 5 °C 10 s 1 s
Reflow:
260 °C 10 s 1 s
Capacitance change
Dissipation factor
Leakage current
Moisture
resistance
no load
Leave at 40 °C and
90 ꢀ to 95 ꢀ RH for 500 h
Shall not exceed 150 ꢀ of initial specified value
Initial specified value or less
Capacitance change
Dissipation factor
Leakage current
Within 20 ꢀ of initial value
High
temperature
load
85 °C. The rated voltage is applied for
2000 h
Initial specified value or less
Shall not exceed 200 ꢀ of initial specified value
Capacitance change
Dissipation factor
Leakage current
Within 20 ꢀ of initial value
Initial specified value or less
Initial specified value or less
Leave at -55 °C, normal temperature,
125 °C, and normal temperature for
30 min, 3 min, 30 min, and 3 min.
Repeat this operation 5 times running
Thermal shock
Capacitance change
Dissipation factor
Leakage current
Within 20 ꢀ of initial value or less
Moisture
resistance
load
Leave at 40 °C and 90 ꢀ to 95 ꢀ RH
The rated voltage is applied for 500 h
Shall not exceed 150 ꢀ of initial specified value
Shall not exceed 200 ꢀ of initial specified value
85 °C. The rated voltage is applied
through a protective resistor of 1 /V.
Failure rate
1 ꢀ / 1000 h
Note
Test conditions per JIS C5101-1
•
Revision: 16-Jan-17
Document Number: 40179
4
For technical questions, contact: polytech@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000