TLE2141M, TLE2141AM
EXCALIBUR LOW-NOISE HIGH-SPEED
PRECISION OPERATIONAL AMPLIFIERS
SGLS059 – NOVEMBER 1990 – REVISED OCTOBER 1991
available features
• Low Noise:
• Low V . . . 500 µV Max at 25°C
• Single or Split Supply . . . 4 V to 44 V
IO
10 Hz . . . 15 nV/√Hz
1 kHz . . . 10.5 nV/√Hz
• Fast Settling Time
• 10000-pF Load Capability
• 20-mA Min Short-Circuit Output Current
• 30-V/µs Min Slew Rate
340 ns to 0.1%
400 ns to 0.01%
• Saturation Recovery . . . 150 ns
• High Gain-Bandwidth Product . . . 5.9 MHz
• Large Output Swing . . . V
+0.1 V
CC–
to V
– 1 V
CC+
SLEW RATE
vs
EQUIVALENT INPUT NOISE VOLTAGE
vs
LOAD CAPACITANCE
FREQUENCY
50
250
200
150
V
R
= ±15 V
CC±
= 100 Ω
S
40
T
A
= –55°C
SR+
30
20
T
A
= 125°C
100
50
0
T
A
= 25°C
SR–
10
V
= ±15 V
CC±
= –1
A
VD
= 25°C
T
A
0
0.01
0.1
1
10
10 k
1
1 k
10
100
f – Frequency – Hz
C
– Load Capacitance – nF
L
description
The TLE2141M and TLE2141AM are high-performance, internally compensated operational amplifiers built
using Texas Instruments complementary bipolar Excalibur process. The TLE2141AM is a tighter offset voltage
grade of the TLE2141M. Both are pin-compatible upgrades to standard industry products.
The design incorporates a patent-pending input stage that simultaneously achieves low audio band noise of
10.5 nV/√Hz with a 10-Hz 1/f corner and symmetrical 40-V/µs slew rate typically with loads up to 800 pF. The
resulting low distortion and high power bandwidth are important in high-fidelity audio applications. A fast settling
time of 340 ns to 0.1% of a 10-V step with a 2-kΩ/100-pF load is useful in fast actuator/positioning drivers. Under
similar test conditions, settling time to 0.01% is 400 ns.
AVAILABLE OPTIONS
PACKAGE
V
max
CHIP FORM
(Y)
IO
T
A
CHIP CARRIER
(FK)
CERAMIC DIP
(JG)
AT 25°C
500 µV
900 µV
TLE2141AMFK
TLE2141MFK
TLE2141AMJG
TLE2141MJG
–55°C to 125°C
TLE2141Y
Copyright 1991, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265