TISP4600F3, TISP4700F3
HIGH VOLTAGE
BIDIRECTIONAL THYRISTOR OVERVOLTAGE PROTECTORS
TISP4600F3, TISP4700F3
Ion-Implanted Breakdown Region
Precise and Stable Voltage
LM Package (Top View)
Low Voltage Overshoot under Surge
T(A)
NC
R(B)
1
2
3
V
DRM
V
V
(BO)
V
Device
MD4XATA
‘4600
‘4700
420
500
600
700
NC - No internal connection on pin 2
Rated for International Surge Wave Shapes
LMF Package (LM Pkg. with Formed Leads) (Top View)
I
TSP
A
T(A)
Wave Shape
Standard
1
2
3
NC
2/10
8/20
GR-1089-CORE
IEC 61000-4-5
FCC Part 68
190
175
110
R(B)
MD4XAKC
10/160
NC - No internal connection on pin 2
Device Symbol
FCC Part 68
10/700
70
ITU-T K.20/21
10/560
FCC Part 68
50
45
T
10/1000
GR-1089-CORE
.......................................UL Recognized Component
Description
These devices are designed to limit overvoltages between a system
and the protective ground. The TISP4700F3 is designed for insulation
protection of systems such as LANs, and allows a float voltage of
500 V without clipping. IEC 60950 and UL 1950 have certain require-
ments for incoming lines of telephone network voltage (TNV). Any pro-
R
SD4XAA
Terminals T and R correspond to the
alternative line designators of A and B
tector from the line to ground must have a voltage rating of 1.6 times the equipment rated voltage. International and European equip-
ment usually have maximum rated voltages of 230 V rms, 240 V rms or 250 V rms. Multiplying the 250 V value by 1.6 gives a protector
VDRM value of 400 V. Allowing for operation down to 0 °C gives a VDRM value of 420 V at 25 °C. This need is met by the TISP4600F3.
The protector consists of a symmetrical voltage-triggered bidirectional thyristor. Overvoltages are initially clipped by breakdown clamping
until the voltage rises to the breakover level, which causes the device to crowbar into a low-voltage on state. This low-voltage on state
causes the current resulting from the overvoltage to be safely diverted through the device. The high crowbar holding current prevents
d.c. latchup as the diverted current subsides. A single device provides 2-point protection. Combinations of devices can be used for multi-
point protection (e.g. 3-point protection between Ring, Tip and Ground).
The TISP4x00F3 is guaranteed to voltage limit and withstand the listed international lightning surges in both polarities. This protection
device is in a DO-92 (LM) cylindrical plastic package.
How To Order
For Standard
For Lead Free
Termination Finish Termination Finish
Device
Package
Carrier
Order As
Order As
TISP4x00F3 LM, Straight Lead DO-92
TISP4x00F3 LM, Straight Lead DO-92
TISP4x00F3 LMF, Formed Lead DO-92
Bulk Pack
TISP4x00F3LM
TISP4x00F3LM-S
Tape And Reel
Tape And Reel
TISP4x00F3LMR TISP4x00F3LMR-S
TISP4x00F3LMFR TISP4x00F3LMFRS
Insert x = 6 for TISP4600F3 and x= 7 for TISP4700F3
*RoHS Directive 2002/95/EC Jan 27 2003 including Annex
NOVEMBER 1997 - REVISED FEBRUARY 2005
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.