TISP2240F3, TISP2260F3, TISP2290F3, TISP2320F3, TISP2380F3
DUAL SYMMETRICAL TRANSIENT
VOLTAGE SUPPRESSORS
Copyright © 1997, Power Innovations Limited, UK
MARCH 1994 - REVISED SEPTEMBER 1997
TELECOMMUNICATION SYSTEM SECONDARY PROTECTION
●
Ion-Implanted Breakdown Region
Precise and Stable Voltage
D PACKAGE
(TOP VIEW)
Low Voltage Overshoot under Surge
1
2
3
4
8
7
6
5
G
G
G
G
T
NC
NC
R
VDRM V(BO)
DEVICE
V
V
‘2240F3
‘2260F3
‘2290F3
‘2320F3
‘2380F3
180
200
220
240
270
240
260
290
320
380
MDXXAE
NC - No internal connection
P PACKAGE
(TOP VIEW)
●
●
Planar Passivated Junctions
Low Off-State Current < 10 µA
T
1
2
8
7
T
G
G
Rated for International Surge Wave Shapes
3
4
G
R
6
5
G
R
ITSP
MDXXAF
WAVE SHAPE
STANDARD
A
175
120
60
Specified T terminal ratings require connection of pins 1 and 8.
Specified R terminal ratings require connection of pins 4 and 5.
2/10 µs
8/20 µs
FCC Part 68
ANSI C62.41
FCC Part 68
FCC Part 68
RLM 88
10/160 µs
10/560 µs
0.5/700 µs
SL PACKAGE
(TOP VIEW)
45
38
FTZ R12
50
1
2
3
T
G
R
10/700 µs
VDE 0433
50
CCITT IX K17/K20
REA PE-60
50
10/1000 µs
35
MDXXAG
MD23AA
●
Surface Mount and Through-Hole Options
device symbol
PACKAGE
Small-outline
Small-outline taped
and reeled
PART # SUFFIX
D
T
R
DR
Plastic DIP
P
Single-in-line
SL
●
UL Recognized, E132482
description
These high voltage dual symmetrical transient
SD2XAA
voltage suppressor devices are designed to
protect telecommunication applications with
battery backed ringing against transients caused
by lightning strikes and a.c. power lines. Offered
in five voltage variants to meet battery and
protection requirements they are guaranteed to
suppress and withstand the listed international
lightning surges in both polarities. Transients are
initially clipped by breakdown clamping until the
voltage rises to the breakover level, which
G
Terminals T, R and G correspond to the
alternative line designators of A, B and C
causes the device to crowbar. The high crowbar
holding current prevents d.c. latchup as the
current subsides.
P R O D U C T
I N F O R M A T I O N
Information is current as of publication date. Products conform to specifications in accordance
with the terms of Power Innovations standard warranty. Production processing does not
necessarily include testing of all parameters.