REVISION AB
TFSDX-XX-XXX-XX-XX.XX-XX-XXX
FEP CABLE OPTION
.110 2.79
REF
-T: FEP
-NXX OPTION (END 2)
(LEAVE BLANK FOR STANDARD
PVC INSULATION)
(ONLY AVAILABLE WITH -D,-DL,-T,-TF,TR)
(SEE SHT 3 FOR -D PINOUT)
(SEE SHT 4 FOR -T PINOUT)
DO NOT
SCALE FROM
THIS PRINT
(No OF POS x .050[1.27])
+ .120[2.54] REF
(SEE NOTE 9)
-NUS: NOTCH UP, STRAIGHT
-NDS: NOTCH DOWN, STRAIGHT
-NUX: NOTCH UP, CROSSED
-NDX: NOTCH DOWN, CROSSED
No OF POSITIONS
-02 THRU -50 (PER ROW)
N
02
C
L
WIRE GAUGE (AWG)
-28, -30
END OPTION
-S: SINGLE END
.153 3.89
REF
.240 6.10
REF
.225 5.72
REF
COLOR CODE
-SL: SINGLE END WITH FRICTION LOCK
(SEE SHEET 2, FIG 4)
LEAVE BLANK FOR ALL BLACK WIRE,
C: COLOR CODED WIRE, SEE TABLE 2, SHEET 2
(NOT AVAILABLE WITH FEP OPTION)
***
** -D: DOUBLE END
01
(SEE SHEET 2, FIG 2)
N-1
PLATING SPECIFICATION
** -T: TRANSFER END
.375 9.53
REF
.050 1.27
REF
-H: 30µ" HEAVY GOLD IN CONTACT AREA,
(SEE SHEET 2, FIG 3 AND SHEET 4)
** -DL: DOUBLE END WITH FRICTION LOCK
FIG 1
3µ" GOLD ON TAIL
-S: SINGLE END
***
"A"
-G: 10µ" LIGHT GOLD IN CONTACT AREA,
10µ" GOLD ON TAIL ON TAIL
-F: 3µ" FLASH GOLD IN CONTACT AREA,
3µ" GOLD ON TAIL
(SEE SHEET 2, FIG 5)
(TFSDX-07-28-XX-XX.XX-S SHOWN)
** -TF: TRANSFER END WITH FRICTION LOCK
***
(SEE SHEET 2, FIG 6)
** -TR: TRANSFER END W/RETENTION LATCH(SEE
SHEET 5)(MUST CHOOSE FROM -NXX OPTIONS)
(ONLY AVAILABLE IN -05 THRU -50 POS)
TFSD-XX-D-S
(SEE NOTE 13)
-GF: 3µ" FLASH GOLD IN CONTACT AREA,
3µ" GOLD ON TAIL
.562 14.26
REF
ASSEMBLED LENGTH
SPECIFY IN INCHES
(SINGLE END: 03.00 INCH [76.2mm] MINIMUM,
DOUBLE OR TRANSFER END: 03.25 INCH [82.6mm]
MINIMUM)
(-GF ONLY AVAILABLE TO EXISTING CUSTOMERS,
SEE –F PLATING)
.238 6.05
REF
T-1M44-2830-XX
** MUST CHOOSE FROM -NXX OPTIONS
*** ONLY AVAILABLE ON POS 5, 7, & 10 - 50
C
XX.XX
(SEE NOTE 12)
DWCX-28-XX-300
TABLE 1
CONTACT
(ONLY USED WITH -T, -TF &
-TR END OPTIONS)
WIRE
GAUGE
SERIES
WIRE
PIN
NOTES:
TFSD
TFSD
TFSDT
28 AWG
30 AWG
28 AWG
DWC-28-XX-300
DWC-30-XX-300
DWCT-28-XX-TC
T-1M44-2830-XX
T-1M44-2830-XX
T-1M44-2830-XX
C-203-2830-XX
C-203-2830-XX
C-203-2830-XX
"A"
SECTION "A"-"A"
C
1.
REPRESENTS A CRITICAL DIMENSION.
2. MINIMUM PULLOUT FORCE: 3 LBS [13.3 N].
3. CONTACT MUST BE INSERTED UNTIL
RETENTION FEATURE LOCKS INTO PLACE.
C
TFSDT
30 AWG
DWCT-30-XX-TC
T-1M44-2830-XX
C-203-2830-XX
F:\DWG\MISC\MKTG\TFSDX-XX-XXX-XX-XX.XX-XX-XXX-MKT.SLDDRW
4. ALL FINISHED GOODS ARE TO BE ELECTRICAL TESTED INCLUDING HI-POT TEST AT 300 V.
AFTER FINAL ELECTRICAL TEST, LABEL EACH ASSEMBLY WITH (1) ET STAMP ON THE BODY.
5. TINNED COPPER WIRE IS RoHS COMPLIANT.
PROPRIETARY NOTE
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
6. PARTS TO BE LAYER PACKAGED.
DECIMALS
ANGLES
2
7. END OF DISCRETE WIRE MUST BE IN THE RANGE AFTER CRIMP.
8. REFER TO CRIMP SPECIFICATIONS PRINT FOR CRIMP AND STRIP DIMENSIONS,
TOLERANCES, TOOLING AND ITS REQUIREMENTS.
.XX: .01 [.3]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733 FAX: 812-948-5047
e-Mail info@SAMTEC.com code 55322
.XXX: .005 [.13]
.XXXX: .0020 [.051]
9. SINGLE ENDED ASSEMBLIES USING THE FEP OPTION ARE FOR CRIMP APPLICATIONS ONLY.
MATERIAL:
SHEET SCALE: 2:1
DO NOT SCALE DRAWING
DESCRIPTION:
10. NOTE DELETED.
11. NOTE DELETED.
INSULATOR: LCP, COLOR: BLACK
CONTACT: BeCu
CABLE INSULATION: SEE CALLOUT
WIRE: DWC: TINNED COPPER.
DWCT: TIN PLATED COPPER
(SEE TABLE 1)
.050[1.27] SOCKET DISCRETE CABLE ASSEMBLY
DWG. NO.
12. FOR LENGTHS LESS THAN 12 IN, TOLERANCE SHALL
BE ±.125[3.18]. FOR OTHER LENGTHS, TOLERANCES SHALL BE ±2%.
13. USE C-203-XXXX-GF.
TFSDX-XX-XXX-XX-XX.XX-XX-XXX
LENNY K
7/18/06
SHEET 1 OF 5
BY: