TC74AC138P/F/FT
Logic Diagram
15
Y0
14
Y1
1
2
3
A
B
C
13
Y2
12
Y3
Select
inputs
Data
outputs
11
10
9
Y4
Y5
Y6
Y7
7
4
5
6
G2A
G2B
G1
Enable
inputs
Absolute Maximum Ratings (Note 1)
Characteristics
Supply voltage range
Symbol
Rating
Unit
V
−0.5 to 7.0
V
V
CC
DC input voltage
V
−0.5 to V
+ 0.5
IN
CC
CC
DC output voltage
Input diode current
Output diode current
DC output current
V
−0.5 to V
+ 0.5
V
OUT
I
±20
mA
mA
mA
mA
mW
°C
IK
I
±50
±50
OK
I
OUT
DC V /ground current
CC
I
±200
CC
Power dissipation
P
500 (DIP) (Note 2)/180 (SOP/TSSOP)
D
Storage temperature
T
stg
−65 to 150
Note 1: Exceeding any of the absolute maximum ratings, even briefly, lead to deterioration in IC performance or
even destruction.
Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the
significant change in temperature, etc.) may cause this product to decrease in the reliability significantly
even if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute
maximum ratings and the operating ranges.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/Derating Concept and Methods) and individual reliability data (i.e. reliability test
report and estimated failure rate, etc).
Note 2: 500 mW in the range of Ta = −40 to 65°C. From Ta = 65 to 85°C a derating factor of −10 mW/°C should be
applied up to 300 mW.
Operating Ranges (Note)
Characteristics
Supply voltage
Symbol
Rating
Unit
V
2.0 to 5.5
V
V
CC
Input voltage
V
0 to V
0 to V
IN
CC
CC
Output voltage
V
V
OUT
Operating temperature
T
−40 to 85
0 to 100 (V = 3.3 ± 0.3 V)
°C
opr
CC
0 to 20 (V
Input rise and fall time
dt/dV
ns/V
= 5 ± 0.5 V)
CC
Note:
The operating ranges must be maintained to ensure the normal operation of the device.
Unused inputs must be tied to either VCC or GND.
3
2012-02-29