Thermal (T- and TA-Line)
www.schurter.com/PG17_18_19
T11-818
Circuit Breaker for Equipment thermal, Drop-in type, Reset type, Solder terminals
Description
- Drop-in type
Applications
- Power tools
- Thermal circuit breaker
- 1-pole
- Reset type
- Household Equipment
- Power supplies and chargers
- Industrial appliances
- Positively trip-free release
- Solder, THT
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, e-Shop,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product, Product News
Standards
- IEC 60934
- UL 1077
- CSA C22.2 235
- GB 17701
Technical Data
Rated Voltage AC
240 V; 50/60 Hz
48 V
0.05 - 16 A
Overload
IEC: min. 40trips
@ 6 x Ir, cos φ 0.6
UL / CSA: min. 50trips
@ 1.5 x Ir, cos φ 0.75
-5°C to 60°C
1.5 mm @ 10 - 60 Hz
acc. to IEC 60068-2-6, test Fc
5 G @ 60 - 500 Hz
acc. to IEC 60068-2-6, test Fc
100 G / 6ms
acc. to IEC 60068-2-27, test Ea
Thermal
Reset type
ca. 10g
Rated Voltage DC
Rated current range AC
Conditional short circuit ca-
pacity
IEC: Inc, PC1, AC 240V: 2kA
Ambient temperature
Vibration Resistance
Short circuit capacity Icn
at In < 6.5 A/240 VAC : 8 x In
at In ≥ 6.5 A/240 VAC : 96 A
from front side IP 40 acc. to IEC 60529
50Hz: > 1.5kV
Impulse 1.2/50 μs: > 2.5kV
500VDC > 100 MΩ
2 x Ir: 500switching cycles
Reset type
AC : 2 x Ir , cos φ 0.6 :
DC : 2 x Ir , L/R = 2 - 3 ms :
50switching cycles
Degree of Protection
Dielectric Strength
Shock Resistance
Insulation resistance
Endurance typical
Endurance minimum
Tripping Type
Actuation type
Weight
1
Circuit Breakers