SXQ50 Series
S i n g l e o u t p u t
DC/DC CONVERTERS 36-50W High Efficiency DC/DC Converters
1
• Surface mount quarter-brick format
• High efficiency topology, 90% at 5V and
86.5% typical at 1.8V
• Low profile, open-frame package
• Wide operating temperature, -40°C to +90°C (with derating)
• 90% to 110% output trim
• No minimum load
• Remote on/off
The SXQ50 series are surface mount high-efficiency, isolated DC/DC converters in a
standard quarter-brick format and a height of just 0.4 inches. The converters provide up to
50 Watts of output power and are capable of delivering very high current at low voltages.
Patent pending technology ensures unprecedented levels of performance from a 50W
surface-mount DC/DC converter. The first four models in the series feature an input
voltage range of 33 to 75VDC and are available with output voltages of 5.0V, 3.3V, 2.5V or
1.8V. The output voltage of each model is adjustable from 90% to 110% of its nominal
value. Typical efficiencies are 90% for the 5V model, 89% for the 3.3V, 88% for the 2.5V
and 86.5% for the 1.8V. All SXQ50 series converters have a remote on/off capability, and
are fully protected against over-voltage, over-temperature and short-circuit conditions.
Featuring full international safety approval, including EN60950 (TÜV Product Service) and
UL/cUL 60950, SXQ50 series converters reduce compliance costs and time to market.
TÜV
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Total error band
Set point accuracy
Line regulation
(See Note 8)
4.5%
2.0% max.
0.3% max.
0.3% max.
90% to 110%
10%
Conducted emissions
EN55022 (See Note 2)
EN55022 (See Note 2)
EN55022
Level A
Level B
Level A
Radiated emissions
Immunity:
ESD air
ESD contact
EFT DC Input
Radiated field enclosure EN61000-4-3 10V/m
Conducted (DC power)
Conducted (signal)
Input transients
Low line to high line
Full load to min. load
EN61000-4-2 8kV, 15kV
EN61000-4-2 6kV, 8kV
EN61000-4-4, 2kV (NP)
Load regulation
Voltage adjustability
EN61000-4-6 10V (NP)
EN61000-4-6 10V (NP)
ETS 300 132-2, ETR 283
Output remote
sense range
(See Note 9)
Minimum load
Overshoot
0A
None
None
GENERAL SPECIFICATIONS
At turn-on and turn-off
5Hz to 20MHz
Efficiency
See table
1500VDC
350kHz
Undershoot
Operational insulation
Switching frequency
Input/output
Fixed
Ripple and noise
120mV pk-pk
30mV rms
Transient response
(See Note 1)
5% max. deviation
200µs recovery to
within total error band
Approvals and
standards (See Note 4)
EN60950 (TÜV Product Service)
UL/cUL60950
Material flammability
Weight
UL94V-0
INPUT SPECIFICATIONS
Input voltage range
Input current
25g (0.88oz)
48Vin nominal
33 to 75VDC
MTBF
MIL-HDBK-217F
@ 40°C, 100% load
ground benign
>292,000 hours
No load
Remote OFF
60mA
25mA
Input current (max.)
(See Note 3)
1.73A max. @ Io max.
and Vin = 33
ENVIRONMENTAL SPECIFICATIONS
Thermal performance Operating temperature -40°C to +90°C
Non-operating -40°C to +125°C
Input reflected ripple
(See Note 5)
110mA (pk-pk)
Active high remote ON/OFF
(See Note 7)
Open collector ref to -input
Open circuit or <12VDC
<1.2VDC
Logic compatibility
International Safety Standard Approvals
ON
OFF
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
file No. E174104
Undervoltage lockout
Power up
Power down
32.5V
30.5V
TÜV TÜV Product Service. Certificate No. B 01 11 38572 029
Start-up time
(See Note 6)
Power up
Remote ON/OFF
10ms
3ms
File Name: SXQ50S.PDF Rev: 09 Oct 2002