General Purpose Relays
SCHRACK
Safety Relay SR6
n
6 pole safety relay with either
4 NO+2 NC or 3 NO+3 NC or 5 NO+1 NC contacts
Forcibly guided contacts according to EN50205
Rated current 8 A
n
n
n
Coil power 800 mW or 1200 mW
Applications
Emergency shut-off, press control, machine control, elevator
and escalator control, safety modules
F0206-EA
Approvals
V
REG.-Nr. 128935,
Z
E214024,
T
968/EL 350.04/09
Technical data of approved types on request
Contact data
Contact configuration
3 NO contacts and 3 NC contacts
4 NO contacts and 2 NC contacts
5 NO contacts and 1 NC contact
single contact, forcibly guided
type A according to EN 50205
micro disconnection
250 / 400 VAC
Contact set
Type of interruption
Rated voltage / max. switching voltage AC
Rated current
Maximum breaking capacity AC
Contact material
8 A
2000 VA
800 mW version
1200 mW version
AgSnO2 + 0,2 μm Au
AgSnO2
Minimum contact load
Contact resistance
10 mA / 5 V
w 100 mOhm / 1 A / 24 VDC
w 20 Ohm / 10 mA / 5 VDC
6 min-1 / 150 min-1
Rated frequency of operation with / without load
Contact ratings
Type Contact Load*)
Ambient
temp. [°C]
Cycles
EN60947-5-1
SR6
SR6
1 NO
1 NO
IEC 947-5-1 (AC15) utilization category 250 VAC / 5 A 23°C
IEC 947-5-1 (DC13) utilization category 24 VDC / 6 A 23°C
6,050
6,050
*) load on one pole
Coil data
Rated coil voltage range DC coil
Operative range
5...110 VDC
2
Coil versions, 800 mW, DC-coil
Coil code
Order. code voltage
Nominal
Operate
voltage
VDC
3.8
Release
voltage
VDC
0.5
Coil
resistance
c
31+10%
45+10%
101+10%
180+10%
405+10%
551+10%
720+10%
1620+10%
2000+10%
2880+10%
4500+10%
9031+10%
15130+10%
Rated coil
power
mW
block 4
K05
K06
K09
K12
K18
K21
K24
K36
K40
K48
K60
K85
L10
VDC
5
6
9
12
18
21
24
36
40
48
60
85
110
806
4.5
0.6
800
6.8
9.0
0.9
802
1.2
800
13.5
15.8
18.0
27.0
30.0
36.0
45.0
63.8
82.5
1.8
800
2.1
800
2.4
800
3.6
800
4.0
800
4.8
800
6.0
800
8.5
800
11.0
800
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
processing information only
to be used together with the
'Definitions' section in the cat-
alogue or at schrackrelays.com
in the ‘Schrack’ section.
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
Specifications subject to
change.