SPU50 SERIES
60W Desk Top Switching Power Supplies For I.T.E.
Description:
The SPU50 series of AC/DC switching mode power supplies
provide 60 Watts of continuous output power. All supplies are
UL 94V-0 compliant, include IEC-320-C14 input for
worldwide applications. All models meet FCC Part-15 class B
and CISPR-22 class B emission Limits and are designed to
comply with UL, C-UL, TUV and CE requirements. All units are
100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Output Voltage Available From 5VDC Thru 50VDC
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage And Over Load protection
Single Output
Splash proof
Class I Insulation
Safety Approvals :
Two years warranty
CB
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
90
47
0
264
63
VAC
Hz
W
Fin Input Frequency
Wo
Vo
Io
Output Power Range
Output Voltage Range
Output Current Range
Vin=90 to 264VAC
60
See rating chart V
See rating chart A
Iil Input Current (Low Line)
Iih Input Current (High Line)
Irl Low Line Inrush Current
Io=Full load, Vin=115VAC
Io=Full load, Vin=230 VAC
1.6
1.0
A
A
Io=Full load, 25°c, Cool start,
12
15
A
Vin=115VAC
Io=Full load, 25°c, Cool start,
Irh High Line Inrush Current
26
30
88
1
A
Vin=230VAC
Eff Efficiency
Io=Full Load, Vin=230VAC
Io=Full Load
75
83
0.5
3
%
%
REG-i Line Regulation
REG-o Load Regulation
OVP Over Voltage Protection
OCP Over Current Protection
Ttr Transient Response
Thold Hold-Up Time
Vin=230VAC
5
%
112
110
132
150
4
%
%
Io=FullLoadtoHalfLoad,Vin=100VAC
Io=Full Load, Vin=100VAC
mS
mS
S
16
Ts
Start Up Time
Io=Full Load, Vin=100VAC
0.3
1
2
1
Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
Tc Temperature Coefficient All output
0.5
%
0.5 0.75
0.04
mA
%/°c
-0.04
Environmental :
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Toper Operating Temperature
Tstg Storage Temperature
0
-40
5
70
85
95
°c
°c
%
Hr
Pd
Relative Humidity
Derate linearly from 100% load at 40°c to 50% load at 70°c