Electric Fuse, Fast Blow, 0.75A, 32VAC, 63VDC, 50A (IR), Surface Mount

SP/3216FF-750MA 技术参数

生命周期:ObsoleteReach Compliance Code:unknown
ECCN代码:EAR99HTS代码:8536.10.00.40
风险等级:5.7Is Samacsys:N
熔断特性:FAST主体宽度:1.6 mm
主体高度:0.9 mm主体长度或直径:3.2 mm
电路保护类型:ELECTRIC FUSEJESD-609代码:e0
焦耳积分标称:安装特点:SURFACE MOUNT
最高工作温度:125 °C最低工作温度:-55 °C
包装方法:TAPE AND REEL物理尺寸:3.2mm x 1.6mm x 0.9mm
额定分断能力:50 A额定电流:0.75 A
额定电压(交流):32 V额定电压(直流):63 V
参考标准:CSA; UL表面贴装:YES
端子面层:TIN LEAD OVER NICKEL端子形状:WRAPAROUND
Base Number Matches:1

SP/3216FF-750MA 数据手册

 浏览型号SP/3216FF-750MA的Datasheet PDF文件第2页 
®
Bu s s m a n n  
S MT Ch ip Fu s e  
S u b m in ia t u re S u rfa c e Mo u n t Fu s e s  
3 2 1 6 FF  
R
R
Dim e ns iona l Da ta  
mm (inches)  
3.20 ± 0.2  
(0.126 ± 0.008)  
1.60 ± 0.2  
(0.063 ± 0.008)  
1A  
0.50 ± 0.25  
(0.020 ± 0.010)  
Ca ta log Sym bol: 3216FF  
Volta ge Ra ting: 32 Volt AC, 63 Volt DC (250mA-3A)  
0.90 + 0.20, -0.15  
(0.035 + 0.008, -0.006)  
32 Volt AC, 32 Volt DC (4-6.5A)  
Inte rrupting Ra ting: 50 Amp AC/DC  
Ge ne ra l Inform a tion:  
Phys ic a l Size :  
• Bussmann SMT Chip Fuses utilize metal film and ultrasonic  
wire bond technologies for superior fusing action and  
enhanced reliability.  
• The fuse element is bonded to a ceramic substrate and  
encapsulated with green-colored glass, providing excellent  
short-circuit performance and environmental integrity.  
• Substrate and coating thermal expansion coefficients are  
closely matched to that of FR-4 epoxy-glass circuit board  
for superior joint reliability.  
EIA SOCM-3216AC (Equivalent to 1206)  
3.2 1.6 0.90mm  
0.126 0.063 0.035 in.  
Age nc y Approva ls :  
UL Recognized, Std. 248-14  
All Ratings - File E19180, Guide JDYX2  
CSA Certified:  
1.5-3A - File 53787, Class 1422-01  
CSA Component Acceptance  
250mA,1A, 4-6.5A - File 53787, Class 1422-30  
• The end terminations are over-plated with nickel and tin-  
lead.  
EIA-RS481 (equivalent to IEC 286, Part 3).  
• Fuses are orientated in embossed pockets with ceramic  
side facing up to facilitate proper mounting (see Electrical  
Characteristics, General Note 4.)  
Tim e -Curre nt Cha ra c te ris tic s  
• Fast acting fuse: Will carry 100% of rated current for a  
minimum of 4 hours, and will open within 5 seconds at  
250% of rated current (250mA-3A).  
3216FF  
(See Table)  
• The 4-6.5A fuses will open within 1 second at 350% of  
rated current.  
Packaging & Ordering Information:  
Tape and Reel: Standard 8mm tape, in compliance with  
Product  
Symbol  
Rated Current  
Package Code  
TR/ 3,000 pcs., on a 178mm reel, 8mm tape width  
SP/ 50 pcs. on tape in a plastic box  
TR1/ 15,000 pcs., on a 330mm reel, 8mm tape width  
CE logo denotes compliance with European Union Low Voltage Directive  
(50-1000 VAC, 75-1500 VDC). Refer to BIF document #8002 or contact  
Bussmann Application Engineering at 636-527-1270 for more information.  
Electrical Characteristics  
Current  
Rating  
(Ampere)  
Mark  
Appearing  
On Part  
Typical Melting  
Integral @ 50A  
(A2 * sec)  
Typical Total  
Clearing Integral  
@ 50A (A2 * sec)  
Typ. Resistance  
@ 10% Rated  
Current (Ohms)  
Typ. Voltage  
Drop @ Rated  
Current (Volts)  
Part Number  
(XX=Package Code)  
AC  
DC  
AC  
DC  
XX/3216FF-250mA  
XX/3216FF-375mA  
XX/3216FF-500mA  
.250  
.375  
.500  
.25  
White Dot  
0.5  
.00016  
.001  
.0014  
.000084  
.0002  
.0019  
.00017  
.0010  
.0016  
.0001  
.0009  
.0026  
4.50  
1.80  
1.15  
1.4  
.73  
.66  
XX/3216FF-750mA  
XX/3216FF-1A  
XX/3216FF-1.5A  
.750  
1
1.5  
.75  
1
1.5  
.0033  
.012  
.047  
.00095  
.007  
.029  
.0033  
.014  
.048  
.0042  
.009  
.034  
.75  
.168  
.098  
.63  
.20  
.18  
XX/3216FF-2A  
XX/3216FF-2.5A  
XX/3216FF-3A  
XX/3216FF-4A  
XX/3216FF-4.5A  
XX/3216FF-5A  
XX/3216FF-6.5A  
2
2.5  
3
4
4.5  
5
2
2.5  
3
4
4.5  
5
.116  
.208  
.426  
.187  
.546  
.663  
.081  
.171  
.359  
.164  
.463  
.619  
.136  
.210  
.507  
.208  
.550  
.668  
.092  
.198  
.369  
.168  
.47  
.623  
3.23  
.063  
.046  
.037  
.019  
.014  
.013  
.0085  
.16  
.14  
.13  
.11  
.10  
.09  
.076  
6.5  
6.5  
2.18  
3.21  
2.21  
General Notes:  
1. AC interrupting rating, melting integral and total clearing integral measured at 32V, unity power factor.  
2. DC interrupting rating, melting integral and total clearing integral measured at 63V (250mA-3A) and 32V (4-6.5A), with a battery source.  
3. Voltage drop measured at 23 ± 3°C ambient temperature with the device mounted on a suitable circuit board trace.  
4. It is recommended that fuses be mounted with ceramic (white) side facing up.  
5. Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended,  
with further derating required at elevated ambient temperatures.  
6. Contact Bussmann if higher ampere ratings are needed.  
Form No. 3216FF  