480W Single Output with PFC Function
SP-480 series
Features :
Universal AC input / Full range
Built in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC fan
High power density 5.18w/in3
Low profile:43mm thickness
Built-in remote ON-OFF control
Built-in remote sense function
Active AC surge current limiting
3 years warranty
SPECIFICATION
MODEL
SP-480-3.3
SP-480-5
SP-480-12
SP-480-15
SP-480-24
SP-480-48
DC VOLTAGE
3.3V
5V
12V
15V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
85A
85A
40A
32A
20A
10A
0 ~ 85A
280.5W
0 ~ 85A
425W
425W
80mVp-p
4.5 ~ 5.5V
2.0%
0 ~ 43A
480W
0 ~ 35A
480W
525W
150mVp-p
13.5 ~ 18V
1.5%
0 ~ 22A
480W
528W
150mVp-p
22 ~ 27.6V
1.0%
0 ~ 11A
480W
528W
240mVp-p
41~ 56V
1.0%
PEAK LOAD(10min.) Note.5 280.5W
RIPPLE & NOISE (max.) Note.2 80mVp-p
516W
120mVp-p
10.8 ~ 13.2V
1.5%
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
2.9 ~ 3.6V
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
0.5%
0.5%
0.3%
0.3%
0.2%
0.2%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
1000ms, 80ms/230VAC
2500ms, 80ms/115VAC at full load
18ms/230VAC
Note.7 85 ~ 264VAC
47 ~ 63Hz
18ms/115VAC at full load
120 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
PF>0.95/230VAC
73%
PF>0.98/115VAC at full load
INPUT
79%
85%
85%
87%
89%
6.5A/115VAC
3.5A/230VAC
40A/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
20A/115VAC
<2mA / 240VAC
87 ~ 103A
87 ~ 103A
45.15 ~ 58.05A
36.75 ~ 47.25A
23.1 ~ 29.7A
11.55 ~ 14.85A
57.6 ~ 67.2V
OVERLOAD
Protection type : Constant current limiting, recovers automatically after conditions is removed
3.8 ~ 4.45V 5.75 ~ 6.75V 13.8 ~ 16.2V 18 ~ 21V 28.8 ~ 33.6V
Protection type : Shut down o/p voltage, re-power on to recover
80 (TSW1) detect on heatsink of power transistor 90 (TSW2) detect on heatsink of power diode
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE Note.4
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
RC+/RC-: 0 ~ 0.8V=power on ; 4 ~ 10V=power off
REMOTE CONTROL
WORKING TEMP.
FUNCTION
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:Short
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
SAFETY &
ISOLATION RESISTANCE
EMC
(Note 6)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2), light industry level, criteria A
HARMONIC CURRENT
EMS IMMUNITY
MTBF
120.5K hrs min. MIL-HDBK-217F (25
)
OTHERS
NOTE
DIMENSION
PACKING
278*127*43mm (L*W*H)
1.7Kg; 6pcs/11.3Kg/0.67CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. TSW1: Detect on heatsink of power transistor.
TSW2: Detect on heatsink of output diode.
5. 33% Duty cycle maximum within every 30 minute. Average output power should not exceed the rated power.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
7. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:SP-480-SPEC 2010-10-18