240W Single Output with PFC Function
SP-240 series
Features :
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC Fan
Built-in fan ON / OFF control
LED indicator for power on
Fixed switching frequency at 90KHz
3 years warranty
SPECIFICATION
MODEL
SP-240-5
SP-240-7.5
SP-240-12
SP-240-15
SP-240-24
SP-240-30
SP-240-48
DC VOLTAGE
5V
7.5V
12V
15V
24V
30V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
45A
32A
20A
16A
10A
8A
5A
0 ~ 45A
225W
0 ~ 32A
240W
150mVp-p
6 ~ 9V
2.0%
0 ~ 20A
240W
150mVp-p
10 ~ 14V
1.0%
0 ~ 16A
240W
150mVp-p
12 ~ 18V
1.0%
0 ~ 10A
240W
150mVp-p
20 ~ 28V
1.0%
0 ~ 8A
240W
150mVp-p
27 ~ 33V
1.0%
0 ~ 5A
240W
150mVp-p
41 ~ 56V
1.0%
RIPPLE & NOISE (max.) Note.2 150mVp-p
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3 2.0%
OUTPUT
4 ~ 6V
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
0.5%
0.5%
0.3%
0.3%
0.2%
0.2%
0.2%
1.0%
1.0%
0.5%
0.5%
0.5%
0.5%
0.5%
800ms, 50ms/230VAC
1500ms, 50ms/115VAC at full load
20ms/230VAC
Note.5 88 ~ 264VAC
47 ~ 63Hz
20ms/115VAC at full load
124 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
PF>0.95/230VAC
79%
PF>0.98/115VAC at full load
86%
INPUT
83%
86%
87%
88%
89%
3.6A/115VAC
1.8A/230VAC
40A/230VAC
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
25A/115VAC
<2mA / 240VAC
105 ~ 135% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
9.4 ~ 10.9V 14.7 ~ 17.5V 19 ~ 22.5V 29.5 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
90 (5V,7.5V), 85 (12V,15V,24V,30V,48V) (TSW1 : detect on heatsink of power transistor)
OVERLOAD
34.7 ~ 41V
57.6 ~ 67.2V
6.3 ~ 7.5V
PROTECTION OVER VOLTAGE
5
5
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
RTH2 40 FAN ON, 35 FAN OFF(Typ.)
FUNCTION
FAN CONTROL
-20 ~ +70 (Refer to "Derating Curve")
WORKING TEMP.
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
SAFETY &
EMC
(Note 4)
EMC IMMUNITY
284K hrs min. MIL-HDBK-217F (25
)
MTBF
OTHERS
NOTE
DIMENSION
PACKING
190*93*50mm (L*W*H)
0.8Kg; 18pcs/15.4Kg/1.04CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:SP-240-SPEC 2011-08-23