5秒后页面跳转
SML-P4-K/LF PDF预览

SML-P4-K/LF

更新时间: 2024-11-22 02:50:39
品牌 Logo 应用领域
爱模 - MSYSTEM /
页数 文件大小 规格书
17页 362K
描述
Single Loop Controller Series

SML-P4-K/LF 数据手册

 浏览型号SML-P4-K/LF的Datasheet PDF文件第2页浏览型号SML-P4-K/LF的Datasheet PDF文件第3页浏览型号SML-P4-K/LF的Datasheet PDF文件第4页浏览型号SML-P4-K/LF的Datasheet PDF文件第5页浏览型号SML-P4-K/LF的Datasheet PDF文件第6页浏览型号SML-P4-K/LF的Datasheet PDF文件第7页 
MODEL: SML  
P4: Pi 4 points  
Single Loop Controller Series  
R2: Ai 2 points (isolated between chs)  
+ Ao 2 points (isolated between chs, current output)  
(power input code K, L not selectable)  
R3: Ai 4 + Ao 4 points  
REMOTE I/O MODULE  
(for NestBus use)  
Functions & Features  
S5: Ai 4 + Di 4 points  
• Remote I/O module for the NestBus use  
• Plugin hardware  
S6: Ao 4 + Do 4 points (relay)  
• Twisted-pair cable transmission  
• Removable terminal block  
• Self-diagnostics  
[2] POWER INPUT  
AC Power  
M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz)  
(Selectable only for SML-R2)  
• Monitor LED provided for contact I/O modules  
K: 85 – 132 V AC (Operational voltage range 85 – 132 V, 50 – 60 Hz)  
L: 170 – 264 V AC (Operational voltage range 170 – 264 V, 50 - 60 Hz)  
DC Power  
OTHER THAN SML-R2  
72  
(2.83)  
R: 24 V DC  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
PWR  
80  
RUN  
(3.15)  
[3] OPTIONS  
Lowpass Filter  
(only for SML-P4)  
blank: Without  
/LF: With  
142  
(5.59)  
mm (inch)  
SML-R2  
72  
(2.83)  
RELATED PRODUCTS  
• Loop configuration builder software (model: SFEW3E)  
Builder software downloadable at M-System’s web site.  
A dedicated cable is required to connect the module to the  
PC. Please refer to the users manual for the Builder software  
for applicable cable types.  
P
R
W
R
80  
(3.15)  
U
N
149  
(5.87)  
GENERAL SPECIFICATIONS  
mm (inch)  
Construction: Plug-in  
Connection  
I/O signal, Power input: M3.5 screw terminals (torque 0.8  
MODEL: SML–[1]-[2][3]  
N·m)  
NestBus, RUN contact output: Euro type connector  
terminal  
ORDERING INFORMATION  
• Code number: SML-[1]-[2][3]  
Specify a code from below each [1] through [3].  
(e.g. SML-A4-K)  
Applicable wire size: 0.2 to 2.5 mm2, stripped length 7 mm  
Screw terminal: Chromated steel  
Housing material: Flame-resistant resin (black)  
Isolation:  
I/O selection codes other than R2: NestBus to I/O to RUN  
contact output to power to FG  
[1] I/O SECTION  
A4: Di 8 points  
R2: NestBus to input 1 to input 2 to output 1 to output 2 to  
RUN contact output to power to FG  
C7: Do 8 points (photo MOSFET relay)  
C8: Do 8 points (relay)  
E5: Di 4 + Do 4 points (relay)  
G3: Ai 8 points  
Power indicator: Red LED turns on when power is supplied.  
RUN indicator: Red LED turns on when data are transmitted  
to the NestBus.  
G4: Ai 4 points  
RUN Output: Contact opens in an abnormality.  
M4: Ao 4 points  
SML SPECIFICATIONS  
ES-6371 Rev.4 Page 1/17  
http://www.m-system.co.jp/  

与SML-P4-K/LF相关器件

型号 品牌 获取价格 描述 数据表
SML-P4-M2 MSYSTEM

获取价格

Single Loop Controller Series
SML-P4-M2/LF MSYSTEM

获取价格

Single Loop Controller Series
SML-P4-R MSYSTEM

获取价格

Single Loop Controller Series
SML-P4-R/LF MSYSTEM

获取价格

Single Loop Controller Series
SMLP5001 BOURNS

获取价格

Surface Mount Line Matching Transformers
SM-LP-5001 BOURNS

获取价格

Surface Mount Line Matching Transformers
SM-LP-5001E BOURNS

获取价格

Surface Mount Line Matching Transformers
SMLP5002 BOURNS

获取价格

Surface Mount Line Matching Transformers
SM-LP-5002 BOURNS

获取价格

Surface Mount Line Matching Transformers
SM-LP-5002B BOURNS

获取价格