SM 700 Series
6 0 0 - 7 0 0 W AT T S P R O G R A M M A B L E D C S U P P LY
Features
• Constant voltage and constant current operation
• Parallel operation master/slave
• EMC standard EN61204-3
• Excellent response to load change
• CE marked
• Optional ethernet, RS232, IEEE 488 programming
• Natural convectional cooling
Specifications
OPERATING
INPUT
Efficiency
87%–89% .
100kHz
Yes
Input voltage
90-132/185-265VAC
48Hz–62Hz
Switching frequency
Frequency
Thermal protection
Programming
Inrush current
Insulation
6.5A @ 230Vac, 30A @ 110Vac.
Analogue Programming of voltage and current by
0-5V.
Input – Output: 3750V rms (8mm creepage)
Input – Case: 2500V rms
Output – Case: 600VDC
Programming speed
See table
Master/Slave operation
Parallel and series operation with equal current
and voltage sharing. In this way two or more SM-
units can together be used as one high power unit.
Voltage and current of the units is controlled by the
master (by potentiometers or by programming).
Series operation up to 600V
OUTPUT
Output voltage
See table
Output voltage adjustment 0%–100%
Output current See table
Output current adjustment 0%–100%
Metering
Digital meters standard
CV/CC mode, OVP triggered LEDs
500,000hrs
Indicators
Resolution
0.03% voltage and current control with 10 turn
potentiometers.
MTBF
Overvoltage protection
SM1540-D: 0-17V, SM7020-D: 0-80V,
SM3004-D: 0-350V.
BATTERY CHARGING
The CV/CC regulated power supplies are suitable for battery charging.
Ask for the special datasheet “BATTERY CHARGING WITH SM-series POWER
SUPPLIES”. This datasheet contains information about protective measures
against accidental battery reversing.
Overload protection
Short circuit protection
Temperature coefficient
Load regulation
Line regulation
Yes
Yes
CV: 5x10-5 per °C, CC: 1x10-4 per °C.
0%–100% load see table.
Line 10% – see table.
See table.
ENVIRONMENTAL
Operating temperature
Humidity
-20°C to 50°C
95% RH max, non condensing, up to 40 °C.
75% RH max, non condensing, up to 50 °C.
Ripple & Noise
Storage temperature
Cooling
-40°C to 85°C
Stability
CV: 3x10-4, CC: 1x10-3
Output impedance
(0-100kHz)
SM1540: <40mΩ, SM7020: <60mΩ,
SM3004: < 700mΩ.
Natural convection
STANDARDS AND APPROVALS
Recovery time
(50%–100% load step): 100µS; 150µS for SM
7020.
Safety standards
EMC standards
EMI standards
MECHANICAL
Mounting
EN60950 / EN61010
Remote sense
2V max. per lead compensation.
EN61204-3, EN61000-6-2
EN61000-6-3 (EN55022B)
Bench or 19" rack mounting