Si8610/20/21/22
LOW-POWER SINGLE AND DUAL-CHANNEL DIGITAL ISOLATORS
Features
High-speed operation
DC to 150 Mbps
No start-up initialization required
Selectable fail-safe mode
Default high or low output
(ordering option)
Precise timing (typical)
Wide Operating Supply Voltage
2.5–5.5 V
Up to 5000 VRMS isolation
10 ns propagation delay
1.5 ns pulse width distortion
0.5 ns channel-channel skew
2 ns propagation delay skew
5 ns minimum pulse width
Transient Immunity 50 kV/µs
AEC-Q100 qualification
Wide temperature range
–40 to 125 °C
60-year life at rated working voltage
High electromagnetic immunity
Ultra low power (typical)
5 V Operation
1.6 mA per channel at 1 Mbps
5.5 mA per channel at 100 Mbps
2.5 V Operation
1.5 mA per channel at 1 Mbps
3.5 mA per channel at 100 Mbps
Schmitt trigger inputs
RoHS-compliant packages
SOIC-16 wide body
SOIC-8 narrow body
Applications
Industrial automation systems
Medical electronics
Hybrid electric vehicles
Isolated ADC, DAC
Motor control
Power inverters
Ordering Information:
Isolated switch mode supplies
Communications systems
See page 27.
Safety Regulatory Approvals
UL 1577 recognized
Up to 5000 VRMS for 1 minute
VDE certification conformity
IEC 60747-5-2
(VDE0884 Part 2)
EN60950-1
CSA component notice 5A approval
IEC 60950-1, 61010-1, 60601-1
(reinforced insulation)
(reinforced insulation)
Description
Silicon Lab's family of ultra-low-power digital isolators are CMOS devices
offering substantial data rate, propagation delay, power, size, reliability, and
external BOM advantages over legacy isolation technologies. The operating
parameters of these products remain stable across wide temperature ranges
and throughout device service life for ease of design and highly uniform
performance. All device versions have Schmitt trigger inputs for high noise
immunity and only require VDD bypass capacitors.
Data rates up to 150 Mbps are supported, and all devices achieve propagation
delays of less than 10 ns. Ordering options include a choice of isolation ratings
(3.75 and 5 kV) and a selectable fail-safe operating mode to control the default
output state during power loss. All products >1 kVRMS are safety certified by
UL, CSA, and VDE, and products in wide-body packages support reinforced
insulation withstanding up to 5 kVRMS
.
Rev. 1.3 6/12
Copyright © 2012 by Silicon Laboratories
Si8610/20/21/22