SFSSX-XX-XXX-XX-XX.XX-XX-XXX
REVISION W
(No OF POS x .050[1.27]) + .021[0.53] REF
01
.070 1.78 REF
FEP CABLE OPTION
-NXX OPTION (END 2)
(ONLY AVAILABLE WITH -D, -DR)
-NUS: NOTCH UP, STRAIGHT
(PIN 1 TO PIN 7)
-T: FEP INSULATION
LEAVE BLANK FOR STANDARD
PVC INSULATION
(SEE NOTE 11)
-NDS: NOTCH DOWN, STRAIGHT
.200 5.08
REF
DO NOT
SCALE FROM
THIS PRINT
No OF POSITIONS
(PIN 1 TO PIN 1)
.095 2.41 REF
-02 THRU -50
END OPTION
(END OPTION COMBINATIONS NOT AVAILABLE)
-S: SINGLE END
WIRE GAUGE (AWG)
-28
-30
.080 2.03 REF
-D: DOUBLE END
(MUST CHOOSE FROM -NXX OPTIONS)
-SR: SINGLE ENDED WITH RETENTION LATCH
(SEE SHEET 3, FIG 3)
FIG 1
COLOR CODE:
-S: SINGLE END
(SFSSX-07-28-X-XX.XX-S SHOWN)
LEAVE BLANK FOR ALL BLACK WIRE
C: COLOR CODED WIRE, SEE TABLE
2, SHT 3 (SEE NOTE 10)
(ONLY AVAILABLE ON -02 THRU -50 POS)
-DR: DOUBLE ENDED WITH RETENTION LATCH
(SEE SHEET 3, FIG 4)
PLATING SPECIFICATION
(ONLY AVAILABLE ON -02 THRU -50 POS)
(MUST CHOOSE FROM -NXX OPTIONS)
(VALUES GIVEN ARE IN MICRO INCHES)
ISDF-XX-S
-H: HEAVY GOLD, 30 Au / 50 Ni MIN ON
CONTACT, 3 Au / 50 Ni MIN ON TAIL
-G: GOLD, 10 Au / 50 Ni MIN ON
.050 1.27 REF
ASSEMBLED LENGTH
SPECIFY IN INCHES
"A"
CONTACT, 3 Au / 50 Ni MIN ON TAIL
-F: FLASH SELECTIVE, 3 Au / 50 Ni MIN ON
CONTACT, 3 AU / 50 NI MIN ON TAIL
-GF: FLASH SELECTIVE, 3 Au / 50 Ni MIN ON
(SINGLE END: 03.00 INCH [76.2mm]
MINIMUM,
DOUBLE END: 03.25 INCH [82.6mm]
MINIMUM)
C .440 11.18
REF
CONTACT, 3 AU / 50 NI MIN ON TAIL
(SEE TABLE 2, SHEET 3)
**
.249 6.32
**: -GF ONLY AVAILABLE TO
EXISTING CUSTOMERS
SEE -F PLATING
REF
"A"
SECTION "A"-"A"
C
XX.XX
(SEE NOTE 8)
C
XX.XX
(SEE NOTE 8)
DWCX-XX-XX-300
(SEE TABLE 1)
FIG 2
-D: DOUBLE END
NOTES:
(SFSSX-07-28-X-XX.XX-D-NUS SHOWN)
C
1.
REPRESENTS A CRITICAL DIMENSION.
(SAME AS FIG 1, UNLESS OTHERWISE STATED)
2. MINIMUM PULLOUT FORCE: 3.0 LBS [13.3 N].
3. CONTACT MUST BE INSERTED UNTIL
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
RETENTION FEATURE LOCKS INTO PLACE.
4. ALL FINISHED GOODS ARE TO BE ELECTICAL TESTED INCLUDING
HI-POT TEST AT 1000 VOLTS DC. AFTER FINAL ELECTICAL TEST,
LABEL EACH ASSEMBLY WITH (1) ET STAMP ON THE BODY.
5. TINNED COPPER WIRE IS RoHS COMPLIANT.
C
TOLERANCES ARE:
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DECIMALS
ANGLES
2
.XX: .01 [.3]
520 PARK EAST BLVD, NEW ALBANY, IN 47150
.XXX: .005 [.13]
PHONE: 812-944-6733
FAX: 812-948-5047
code 55322
6. PARTS TO BE LAYER PACKAGED.
.XXXX: .0020 [.051]
e-Mail info@SAMTEC.com
7. END OF DISCRETE WIRE MUST BE IN THE RANGE AFTER CRIMP.
8. FOR LENGTHS LESS THAN 12 in, TOLERANCE SHALL BE +/-.125.
FOR OTHER LENGTHS, TOLERANCE SHALL BE +/-2%.
SHEET SCALE: 2:1
DO NOT SCALE DRAWING
MATERIAL:
DESCRIPTION:
INSULATOR: LCP, COLOR: BLACK
CONTACT: BeCu
.050[1.27] SOCKET DISCRETE CABLE ASSEMBLY
DWG. NO.
9. REFER TO CRIMP SPECIFICATIONS PRINT FOR CRIMP AND STRIP DIMENSIONS,
TOLERANCES, TOOLING, AND ITS REQUIREMENTS.
CABLE INSULATION: PVC OR FEP
WIRE: DWC: TINNED COPPER, DWCT: TIN PLATED COPPER
(SEE TABLE 1)
SFSSX-XX-XXX-XX-XX.XX-XX-XXX
10. COLOR CODED CABLE NOT AVAILABLE WITH SFSST (FEP).
11. ASSEMBLIES USING THE FEP OPTION ARE FOR CRIMP APPLICATIONS ONLY.
SHEET 1 OF 3
BY:
GAYNOR 6/12/2008
F:\DWG\MISC\MKTG\SFSSX-XX-XXX-XX-XX.XX-XX-XXX-MKT.SLDDRW