SF 2010
SF 2012
GENERAL PURPOSE IEC INLET FILTER WITH
INTEGRAL SINGLE OR DOUBLE FUSEHOLDER.
2 & 6 AMP STANDARD & SURGE PROT’
2 & 6 AMP MEDICAL VERSION
db
db
90
80
70
60
50
40
30
20
10
90
SYMMETRIC
80
70
60
50
40
30
20
10
SYMMETRIC
ASYMMETRIC
ASYMMETRIC
.1
.1
.15
.4
1
4
10
40
100
500
.15
.4
1
4
10
40
100
500
Fre que ncy MHz
Fre que ncy MHz
2 & 6 AMP EARTH LINE CHOKE &
EARTH`LINE CHOKE SURGE PROTECTED
db
90
SYMMETRIC
80
70
60
50
40
30
20
10
ASYMMETRIC
.1
.15
.4
1
4
10
40
100
500
Fre que ncy MHz
SF 2010
SF 2012
Rated
Leakage Current
Inductance
Connections
Input
Resistor
Value MΩ
Number
of Fuses
Approvals
Current A @ 250V 50Hz
L1 mH
L2 µH
Output
ꢁ
ꢂ
ꢀ
Standard Version
SF 2010-2/01
SF 2012-2/01
SF 2010-6/01
SF 2012-6/01
2
2
6
6
0.2mA
0.2mA
0.2mA
0.2mA
2.0
2.0
0.5
0.5
IEC 320
IEC 320
IEC 320
IEC 320
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
1
1
1
1
1
2
1
2
■
■
■
■
■
■
■
■
■
■
■
■
Medical Version
SF 2010M-2/01
SF 2012M-2/01
SF 2010M-6/01
SF 2012M-6/01
2
2
6
6
5µA
5µA
5µA
5µA
2.0
2.0
0.5
0.5
IEC 320
IEC 320
IEC 320
IEC 320
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
1
1
1
1
1
2
1
2
■
■
■
■
■
■
■
■
■
■
■
■
Surge Protected Version (IEC 950 not applicable)
SF 2010Z-2/01
SF 2012Z-2/01
SF 2010Z-6/01
SF 2012Z-6/01
2
2
6
6
0.2mA
0.2mA
0.2mA
0.2mA
2.0
2.0
0.5
0.5
IEC 320
IEC 320
IEC 320
IEC 320
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
1
1
1
1
1
2
1
2
■
■
■
■
■
■
■
■
■
■
■
■
Earth Line Choke Version
SF 2010E-2/01
SF 2012E-2/01
SF 2010E-6/01
SF 2012E-6/01
2
2
6
6
0.2mA
0.2mA
0.2mA
0.2mA
2.0
2.0
0.5
0.5
300
300
300
300
IEC 320
IEC 320
IEC 320
IEC 320
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
1
1
1
1
1
2
1
2
■
■
■
■
■
■
■
■
■
■
■
■
Earth Line Choke, Surge Protected (IEC 950 not applicable)
SF 2010EZ-2/01
SF 2012EZ-2/01
SF 2010EZ-6/01
SF 2012EZ-6/01
2
2
6
6
0.2mA
0.2mA
0.2mA
0.2mA
2.0
2.0
0.5
0.5
300
300
300
300
IEC 320
IEC 320
IEC 320
IEC 320
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
6.3 x 0.8 Faston
1
1
1
1
1
2
1
2
■
■
■
■
■
■
■
■
■
■
■
■
Temperature Range: -250C to + 850C
Operating Voltage: 250Vac
Operating Frequency: 0 to 400Hz
Test Voltage: L+ N to ground, 2700Vdc,
2 seconds
Varistor
■■■Approved
■■■Submitted for Approval
Zinc oxide type; energy absorption 21
Joules (current impulse defined in
IEC 60-2 Section 6). Varistor voltage:
430Vdc(measured at 1mA); clamping
voltage 710V at 10A
IEC 950 (EN 60950) Applications
Twin fused version only
Continued on next page
18
FOR MORE INFORMATION PLEASE PHONE 01638 665161