SinglFuse™ꢀSF-1206HIxxxMꢀSeriesꢀFeatures
nꢀ Singleꢀblowꢀfuseꢀforꢀovercurrentꢀ
protection
nꢀ Surfaceꢀmountꢀpackagingꢀforꢀautomatedꢀ
assembly
nꢀ 3216ꢀ(EIAꢀ1206)ꢀfootprint
nꢀ Highꢀinrushꢀcurrentꢀwithstandꢀfuse
nꢀ ULꢀ248-14ꢀlisted
E
nꢀ RoHSꢀcompliant*ꢀandꢀhalogenꢀfree**
nꢀ MultilayerꢀSMDꢀdesign
ꢀ
SF-1206HIxxxMꢀSeriesꢀ-ꢀHighꢀInrushꢀMultilayerꢀSurfaceꢀMountꢀFuses
Electrical Characteristics
Rated Current
(Amps)
Resistance
(Ω) Typ.***
0.340
Rated
Voltage
Interrupting
Rating
Typical
I2t (A2s) ****
0.11
Model
Fusing Time
SF-1206HI100M-2
SF-1206HI150M-2
SF-1206HI200M-2
SF-1206HI250M-2
SF-1206HI300M-2
SF-1206HI350M-2
SF-1206HI400M-2
SF-1206HI450M-2
SF-1206HI500M-2
SF-1206HI600M-2
SF-1206HI700M-2
SF-1206HI800M-2
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
5.00
6.00
7.00
8.00
0.150
0.090
0.065
0.035
0.029
0.023
0.021
0.017
0.013
0.010
0.009
DC 63 V
DC 32 V
DC 24 V
DC 63 V 50 A
DC 32 V 50 A
DC 24 V 80 A
0.33
0.80
1.19
1.35
1.84
2.74
3.20
5.50
12.50
30.00
60.00
Open within 60
sec. at 200 %
rated current
***ꢀ Resistanceꢀvalueꢀmeasuredꢀwithꢀ≤10ꢀ%ꢀratedꢀcurrentꢀatꢀ25ꢀ°Cꢀambient.
2
**** Melting I t calculated at 1000 % of current rating.
Reliability Testing
No.
Test
Requirement
Test Condition
Test Reference
MIL-STD-202
Method 208
1
Solderability
Minimum 95 % coverage
Oneꢀdipꢀatꢀ245ꢀ°Cꢀforꢀ5ꢀseconds
Soldering heat
resistance
DCRꢀchangeꢀ≤ꢀ10ꢀ%
No mechanical damage
MIL-STD-202
Method 210
2
3
4
5
6
7
Oneꢀdipꢀatꢀ260ꢀ°Cꢀforꢀ60ꢀseconds
10ꢀcycles
DCRꢀchangeꢀ≤ꢀ±15ꢀ%ꢀ
No excessive corrosion
MIL-STD-202
Method 106
Moisture resistance
Saltꢀspray
DCRꢀchangeꢀ≤ꢀ±10ꢀ%ꢀ
No excessive corrosion
MIL-STD-202
Method 101
48 hour exposure, 5 % salt solution
DCRꢀchangeꢀ≤ꢀ±10ꢀ%ꢀ
No mechanical damage
0.4ꢀinchꢀD.A.ꢀorꢀ30ꢀGꢀbetweenꢀ
5-3000 Hz
MIL-STD-202
Method 204
Mechanicalꢀvibration
Mechanical shock
Thermal Shock
DCRꢀchangeꢀ≤ꢀ±10ꢀ%ꢀ
No mechanical damage
MIL-STD-202
Method 213
1500 G, 0.5 ms, half-sine shocks
DCRꢀchangeꢀ≤ꢀ±10ꢀ%ꢀ
No mechanical damage
MIL-STD-202
Method 107
100ꢀcyclesꢀbetweenꢀ-65ꢀ°Cꢀandꢀ+125ꢀ°C
No electrical “opens” during testing
Voltageꢀdropꢀchangeꢀshallꢀbeꢀlessꢀ
thanꢀ±20ꢀ%ꢀofꢀinitialꢀvalue
80 % rated current (75 % for < 1 A fuses)
forꢀ2000ꢀhoursꢀatꢀambientꢀtemperatureꢀ
betweenꢀ+20ꢀ°Cꢀandꢀ+30ꢀ°C
Refer to STP
document
8
Life
Agency Recognition
Asia-Pacific: Tel: +886-2 2562-4117 • Email: asiacus@bourns.com
EMEA: Tel: +36 88 520 390 • Email: eurocus@bourns.com
The Americas: Tel: +1-951 781-5500 • Email: americus@bourns.com
www.bourns.com
ULꢀFileꢀNumber .................................................... E198545
http://www.ul.com/ꢀꢀ FollowꢀlinkꢀtoꢀOnlineꢀCertificatesꢀDirectory,ꢀ
then enter UL File No. E198545, or click here
*ꢀꢀꢀ RoHSꢀDirectiveꢀ2002/95/ECꢀJan.ꢀ27,ꢀ2003ꢀincludingꢀannexꢀandꢀRoHSꢀRecastꢀ2011/65/EUꢀJuneꢀ8,ꢀ2011.ꢀ
**ꢀ Bournsꢀconsidersꢀaꢀproductꢀtoꢀbeꢀ“halogenꢀfree”ꢀifꢀ(a)ꢀtheꢀBromineꢀ(Br)ꢀcontentꢀisꢀ900ꢀppmꢀorꢀless;ꢀ(b)ꢀtheꢀChlorineꢀ(Cl)ꢀcontentꢀisꢀ900ꢀppmꢀorꢀless;ꢀandꢀ(c)ꢀtheꢀtotalꢀBromineꢀ(Br)ꢀandꢀꢀ
ꢀ
Chlorineꢀ(Cl)ꢀcontentꢀisꢀ1500ꢀppmꢀorꢀless.
“SinglFuse”ꢀisꢀaꢀtrademarkꢀofꢀBourns,ꢀInc.ꢀ
Specificationsꢀareꢀsubjectꢀtoꢀchangeꢀwithoutꢀnotice.
Theꢀdeviceꢀcharacteristicsꢀandꢀparametersꢀinꢀthisꢀdataꢀsheetꢀcanꢀandꢀdoꢀvaryꢀinꢀdifferentꢀapplicationsꢀandꢀactualꢀdeviceꢀperformanceꢀmayꢀvaryꢀoverꢀtime.
Usersꢀshouldꢀverifyꢀactualꢀdeviceꢀperformanceꢀinꢀtheirꢀspecificꢀapplications.