5秒后页面跳转
SDR250AS54-F PDF预览

SDR250AS54-F

更新时间: 2024-11-25 06:11:03
品牌 Logo 应用领域
XPPOWER /
页数 文件大小 规格书
4页 285K
描述
AC-DC Power Supplies

SDR250AS54-F 数据手册

 浏览型号SDR250AS54-F的Datasheet PDF文件第2页浏览型号SDR250AS54-F的Datasheet PDF文件第3页浏览型号SDR250AS54-F的Datasheet PDF文件第4页 
250 Watts  
SDR Series  
xppower.com  
3.2” x 5” Footprint  
Fits 1U Applications  
Low Leakage Current Option  
Up to 600 W Peak Power  
Single & Dual Outputs  
Top Fan & Convection-cooled Versions  
Output Voltages from 5 V to 60 V  
Specification  
Input  
General  
Input Voltage  
• 90-132 VAC/180-264 VAC,  
auto ranging  
Efficiency  
• Single output models: 3.3 V & 5 V models  
70ꢀ, 12 V models 80ꢀ, all other models  
>83ꢀ at 230 V & full load. Dual output  
models: >70ꢀ at 230 V & full load  
Input Frequency  
Input Current  
• 47-63 Hz  
• 6 A at 115 VAC, 3 A at 230 VAC  
Isolation  
• 3000 VAC Input to Output  
1500 VAC Input to Ground  
100 VDC Output to Ground  
Inrush Current  
• Max 70 A at 230 VAC, 35 A at 115 VAC,  
cold start  
Power Factor  
To EN61000-3-2 Class A  
Switching Frequency  
Power Density  
Signals  
• 30 kHz typical  
• 10.4 W/in3  
Earth Leakage Current • <1.5 mA at 264 VAC,  
option ‘-L’ 500 µA leakage current  
• Power Good goes Hi 100-500 ms after  
output is in regulation and goes Lo at least  
1 ms before loss of regulation  
Input Protection  
• Fitted with a T6.3 A/250 V fuse on dual  
output models, T8 A/250 V fuse on single  
output models  
MTBF  
• 100 kHrs to MIL-HDBK-217F  
Output  
Environmental  
Output Voltage  
• See tables  
Operating Temperature • 0 °C to +70 °C, derate at 2.5ꢀ/ °C from  
+50 °C to +70 °C for single output &  
forced air cooled dual output models.  
For convection cooled dual output  
Output Voltage Trim  
5ꢀ on V1 ꢁV2 of dual output models will  
track by same ꢀ of adjustment)  
Initial Set Accuracy  
Minimum Load  
1ꢀ  
• 1ꢀ on single output models,  
10ꢀ on dual output models  
models, see note 7.  
Storage Temperature  
Operating Humidity  
Storage Humidity  
Cooling  
• -20 °C to +85 °C  
Start Up Delay  
Start Up Rise Time  
Hold Up Time  
• 1.5 s max at 120 VAC  
• 50 ms typical  
• 5-90ꢀ, non-condensing  
• 5-90ꢀ, non-condensing  
• 20 ms min at 80ꢀ of full load  
• ‘-F’ version has built-in fan, others require  
16 CFM to meet forced air ratings  
Line Regulation  
Load Regulation  
0.5ꢀ  
1ꢀ 1-100ꢀ load for single outputs  
3ꢀ V1, 7ꢀ V2 for dual outputs  
ꢁexcept 0312 & 0512 models, 10ꢀ  
regulation on V2)  
Operating Altitude  
Vibration  
• 3000 m  
• 5-50 Hz, acceleration 7.35 m/s2 on  
X, Y and Z axis  
Over/Undershoot  
• 5ꢀ max  
EMC & Safety  
Transient Response  
• 5ꢀ max deviation, recovery to within  
1ꢀ in 500 µs for a 50ꢀ load change  
Emissions  
• FCC Part 15 & EN55022  
Level B conducted  
Ripple & Noise  
• 1ꢀ pk-pk, see note 3  
Harmonic Currents  
ESD Immunity  
Radiated Immunity  
EFT/Burst  
• EN61000-3-2, EN61000-3-3  
Overvoltage Protection • 105-130ꢀ Vnom on output V1,  
• EN61000-4-2, level 3 Perf Criteria A  
• EN61000-4-3, 3 V/m Perf Criteria A  
• EN61000-4-4, level 2 Perf Criteria A  
• EN61000-4-5, level 3 Perf Criteria A  
• EN61000-4-6, 3V Perf Criteria A  
recyle input to reset  
Overtemperature  
Protection  
• Measured internally with auto recovery  
Surge  
Overload Protection  
• 110-140ꢀ  
Conducted Immunity  
Dips & Interruptions  
Short Circuit Protection Trip & restart ꢁHiccup mode), auto recovery  
T
T
• EN61000-4-11 70ꢀ U for 10 ms, 40ꢀ U  
Remote On/Off  
Fan Supply  
• Requires a low signal to inhibit output  
T
for 100 ms, <5ꢀ U for 5000 ms  
• 12 VDC, 300 mA, not available on  
‘-F’ version with built-in fan  
Perf Criteria A, B, B  
• UL60950-1, CSA C22.2 No. 950,  
EN60950-1:2001, CE Mark LVD  
Safety Approvals  

与SDR250AS54-F相关器件

型号 品牌 获取价格 描述 数据表
SDR250AS60 XPPOWER

获取价格

AC-DC Power Supplies
SDR250AS60-F XPPOWER

获取价格

AC-DC Power Supplies
SDR2G SSDI

获取价格

1 AMP 400-1200 50-80nsec ULTRA FAST RECTIFIER
SDR2GSM SSDI

获取价格

1 AMP 400-1000 50-70nsec ULTRA FAST RECTIFIER
SDR2GSMS SSDI

获取价格

1 AMP 400-1000 50-70nsec ULTRA FAST RECTIFIER
SDR2HF1.8 SSDI

获取价格

2 AMPS 1800 - 2000 VOLTS 35 nsec HYPER FAST RECOVERY RECTIFIER
SDR2HF1.8_1 SSDI

获取价格

HYPER FAST RECOVERY RECTIFIER
SDR2HF1.8S SSDI

获取价格

Rectifier Diode, 1 Phase, 1 Element, 2A, 1800V V(RRM), Silicon, HERMETIC SEALED PACKAGE-2
SDR2HF1.8SMS SSDI

获取价格

2 AMPS 1800 - 2000 VOLTS 35 nsec HYPER FAST RECOVERY RECTIFIER
SDR2HF1.8SMSS SSDI

获取价格

Rectifier Diode, 1 Phase, 1 Element, 2A, 1800V V(RRM), Silicon, HERMETIC SEALED PACKAGE-2