VOLTAGE RANGE - 20 to 100 Volts
CURRENT - 10 Amperes
FEATURES
* Metal to silicon rectifier majority carrier conduction
* Low power loss, High efficiency
* High current capability
TO-251
* Low forward voltage drop
* High surge capacity
.268(6.8)
* For use in low voltage high frequency inverters, free
wheeling, and polarity protection applications
.252(6.4)
.022(0.6)
.217(5.5)
.018(0.5)
.205(5.2)
.063(1.6)
.055(1.4)
MECHANICAL DATA
2
.284(7.2)
.268(6.8)
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Terminals: Solder plated, solderable per
MIL-STD-750, Method 2026
* Mounting position: Any
1
2
3
.059(1.5)
.035(0.9)
.035
Max
.256
(6.5)
(0.9)
.032
Min
.024(0.6)
.018(0.4)
* Weight: 0.4 grams Approx.
Max
(0.8)
.181
(4.6)
.095(2.4)
.087(2.2)
Typ
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25oC ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
no suffix
"Y" suffixed
"C" suffixed
1
3
1
3
3
2
2
2
Dimensions in inches and (millimeters)
SYMBOL
UNITS
Volts
SD1020 SD1030 SD1040 SD1050 SD1060 SD1080 SD10100
V
V
RRM
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
20
14
20
30
21
30
40
28
40
50
35
50
60
42
60
80
56
80
100
70
RMS
Volts
Volts
V
DC
O
Maximum DC Blocking Voltage
100
Maximum Average Forward Rectified Current
at TC
=75oC
I
10
Amps
Amps
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC Method)
I
FSM
150
Maximum Instantaneous Forward Voltage at 5.0A DC for "C suffixed",
and at 10A DC for "Y suffixed" & "no suffix"
0.85
0.65
0.75
V
F
Volts
2.0
50
@T
@T
A
A
= 25oC
= 100oC
Maximum DC Reverse Current at
Rated DC Blocking Voltage
mAmps
I
R
Typical Thermal Resistance (Note1)
Typical Junction Capacitance (Note 2)
Storage Operating Temperature Range
Rθ JA
80
0C/W
pF
0C
CJ
700
T
J
, TSTG
-55 to + 125
Note : 1. Mounted on PC Board with 14mm2(0.013mm thick) copper pad areas.
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.